Literature DB >> 15508171

Floating table isotropic projection (FLIPR) acquisition: a time-resolved 3D method for extended field-of-view MRI during continuous table motion.

Sean B Fain1, Fred J Browning, Jason A Polzin, Jiang Du, Yong Zhou, Walter F Block, Thomas M Grist, Charles A Mistretta.   

Abstract

In this work, 3D vastly undersampled isotropic projection (VIPR) acquisition is used simultaneously with continuous table motion to extend the superior/inferior (S/I) FOV for MR angiograms. The new technique is termed floating table isotropic PR (FLIPR). The use of 3D PR in conjunction with table motion obviates the need to locate and prescribe imaging volumes containing the major blood vessels over the large superior-inferior (S/I) ranges encountered in whole-body imaging. In addition, the FLIPR technique provides extended anterior-posterior (A/P) abdominal coverage, isotropic spatial resolution, and temporal resolution. In volunteer studies, FLIPR MR angiograms with 1.6-mm isotropic spatial resolution that approached whole body in extent were acquired in less than 2 min. (c) 2004 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2004        PMID: 15508171     DOI: 10.1002/mrm.20235

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Continuously moving table MRI with SENSE: application in peripheral contrast enhanced MR angiography.

Authors:  Houchun H Hu; Ananth J Madhuranthakam; David G Kruger; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

2.  Variable field of view for spatial resolution improvement in continuously moving table magnetic resonance imaging.

Authors:  Houchun H Hu; Ananth J Madhuranthakam; David G Kruger; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

Review 3.  Whole-Body MRA.

Authors:  Harald Kramer; Harald H Quick; Bernd Tombach; Stefan O Schoenberg; Joerg Barkhausen
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

Review 4.  Sub-Nyquist acquisition and constrained reconstruction in time resolved angiography.

Authors:  Charles A Mistretta
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

5.  Time-resolved bolus-chase MR angiography with real-time triggering of table motion.

Authors:  Casey P Johnson; Clifton R Haider; Eric A Borisch; James F Glockner; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

6.  Continuously moving table MRI with golden angle radial sampling.

Authors:  Saikat Sengupta; David S Smith; E Brian Welch
Journal:  Magn Reson Med       Date:  2014-12-02       Impact factor: 4.668

  6 in total