Literature DB >> 16149061

Continuously moving table MRI with SENSE: application in peripheral contrast enhanced MR angiography.

Houchun H Hu1, Ananth J Madhuranthakam, David G Kruger, James F Glockner, Stephen J Riederer.   

Abstract

An integration of SENSitivity Encoding (SENSE) with continuously moving table (CMT) MRI for extended field-of-view (FOV) acquisitions is described. In this work, the approach in which receiver coils are attached to the object and move in synchrony with the scanner table is considered. Technical issues dealing with the implementation of SENSE-CMT are addressed, including coil calibration, correction for non-uniform magnetic gradients, and specific reconstruction steps. An explanation of combining SENSE with gradient non-linearity correction is given, as the latter becomes necessary in CMT acquisitions where a large sampling FOV is used. It is hypothesized that SENSE can provide at least a 2-fold improvement in lateral spatial resolution compared to non-accelerated CMT acquisitions. The hypothesis is tested in phantoms, where the effectiveness of both SENSE and gradient non-linearity correction to improve spatial resolution is shown. The SENSE-CMT technique is further demonstrated in vivo with contrast-enhanced MR angiography of the peripheral vasculature. Copyright 2005 Wiley-Liss, Inc.

Mesh:

Year:  2005        PMID: 16149061      PMCID: PMC2716116          DOI: 10.1002/mrm.20639

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Improved multi-station peripheral MR angiography with a dedicated vascular coil.

Authors:  M Goyen; S G Ruehm; J Barkhausen; K Kröger; M E Ladd; K H Truemmler; S Bosk; M Requardt; A Reykowski; J F Debatin
Journal:  J Magn Reson Imaging       Date:  2001-03       Impact factor: 4.813

3.  Utilizing SENSE to achieve lower station sub-millimeter isotropic resolution and minimal venous enhancement in peripheral MR angiography.

Authors:  Jeffrey H Maki; Gregory J Wilson; William B Eubank; Romhild M Hoogeveen
Journal:  J Magn Reson Imaging       Date:  2002-04       Impact factor: 4.813

4.  Extended field-of-view imaging with table translation and frequency sweeping.

Authors:  Yudong Zhu; Charles L Dumoulin
Journal:  Magn Reson Med       Date:  2003-06       Impact factor: 4.668

Review 5.  Implications of SENSE MR in routine clinical practice.

Authors:  Johan S van den Brink; Yuji Watanabe; Christiane K Kuhl; Taylor Chung; Raja Muthupillai; Marc Van Cauteren; Kei Yamada; Steven Dymarkowski; Jan Bogaert; Jeff H Maki; Celso Matos; Jan W Casselman; Romhild M Hoogeveen
Journal:  Eur J Radiol       Date:  2003-04       Impact factor: 3.528

6.  Helical MR: continuously moving table axial imaging with radial acquisitions.

Authors:  Ajit Shankaranarayanan; Robert Herfkens; Brian M Hargreaves; Jason A Polzin; Juan M Santos; Jean H Brittain
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

7.  Correction for gradient nonlinearity in continuously moving table MR imaging.

Authors:  Jason A Polzin; David G Kruger; David H Gurr; Jean H Brittain; Stephen J Riederer
Journal:  Magn Reson Med       Date:  2004-07       Impact factor: 4.668

8.  Dual-velocity continuously moving table acquisition for contrast-enhanced peripheral magnetic resonance angiography.

Authors:  David G Kruger; Stephen J Riederer; Jason A Polzin; Ananth J Madhuranthakam; Houchun H Hu; James F Glockner
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

9.  Continuously moving table SENSE imaging.

Authors:  Jochen Keupp; Bernd Aldefeld; Peter Börnert
Journal:  Magn Reson Med       Date:  2005-01       Impact factor: 4.668

10.  Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI.

Authors:  David G Kruger; Stephen J Riederer; Roger C Grimm; Phillip J Rossman
Journal:  Magn Reson Med       Date:  2002-02       Impact factor: 4.668

View more
  4 in total

1.  Correction of B 0-induced geometric distortion variations in prospective motion correction for 7T MRI.

Authors:  Uten Yarach; Chaiya Luengviriya; Daniel Stucht; Frank Godenschweger; Peter Schulze; Oliver Speck
Journal:  MAGMA       Date:  2016-02-09       Impact factor: 2.310

2.  Correction of gradient nonlinearity artifacts in prospective motion correction for 7T MRI.

Authors:  Uten Yarach; Chaiya Luengviriya; Appu Danishad; Daniel Stucht; Frank Godenschweger; Peter Schulze; Oliver Speck
Journal:  Magn Reson Med       Date:  2014-05-05       Impact factor: 4.668

Review 3.  Motion correction in MRI of the brain.

Authors:  F Godenschweger; U Kägebein; D Stucht; U Yarach; A Sciarra; R Yakupov; F Lüsebrink; P Schulze; O Speck
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

4.  Continuously moving table MRI with golden angle radial sampling.

Authors:  Saikat Sengupta; David S Smith; E Brian Welch
Journal:  Magn Reson Med       Date:  2014-12-02       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.