Free-breathing radial acquisitions of the heart.

Kate McLeish1, Sebastian Kozerke, William R Crum, Derek L G Hill.   

Abstract

There is considerable interest in performing free-breathing acquisitions of the heart in order to obtain high-quality images without the need for multiple, long breathholds. In this article a 3D motion-correction method is described that is based on image registration of in-plane data and through-plane slice tracking. A number of fast radial undersampled images are acquired, each of which is free of motion artifacts. Initially, in-plane translational and rotational motion between each image was corrected before combining the data to give a fully sampled image. At the next stage, correction of in-plane deformation, in addition to translations and rotations, was performed in the image domain. Through-plane translational motion was compensated using a navigator echo to move the acquisition plane. Using this method, information on the motion of the heart was captured at the same time as acquiring the image data. No motion model, assumptions about the motion, or training data are required. The method is demonstrated on phantom data and cardiac images acquired on free-breathing volunteers. (c) 2004 Wiley-Liss, Inc.

Mesh:

Year:  2004        PMID: 15508161     DOI: 10.1002/mrm.20252

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Retrospective motion correction protocol for high-resolution anatomical MRI.

Authors:  Peter Kochunov; Jack L Lancaster; David C Glahn; David Purdy; Angela R Laird; Feng Gao; Peter Fox
Journal:  Hum Brain Mapp       Date:  2006-12       Impact factor: 5.038

Review 2.  Highly accelerated cardiovascular MR imaging using many channel technology: concepts and clinical applications.

Authors:  Thoralf Niendorf; Daniel K Sodickson
Journal:  Eur Radiol       Date:  2007-06-12       Impact factor: 5.315

3.  Three-dimensional late gadolinium enhancement imaging of the left atrium with a hybrid radial acquisition and compressed sensing.

Authors:  Ganesh Adluru; Liyong Chen; Seong-Eun Kim; Nathan Burgon; Eugene G Kholmovski; Nassir F Marrouche; Edward V R Dibella
Journal:  J Magn Reson Imaging       Date:  2011-10-03       Impact factor: 4.813

4.  3D radial sampling and 3D affine transform-based respiratory motion correction technique for free-breathing whole-heart coronary MRA with 100% imaging efficiency.

Authors:  Himanshu Bhat; Lan Ge; Sonia Nielles-Vallespin; Sven Zuehlsdorff; Debiao Li
Journal:  Magn Reson Med       Date:  2011-01-10       Impact factor: 4.668

5.  Beat-to-beat respiratory motion correction with near 100% efficiency: a quantitative assessment using high-resolution coronary artery imaging.

Authors:  Andrew D Scott; Jennifer Keegan; David N Firmin
Journal:  Magn Reson Imaging       Date:  2011-02-02       Impact factor: 2.546

6.  Self-navigation with compressed sensing for 2D translational motion correction in free-breathing coronary MRI: a feasibility study.

Authors:  Gabriele Bonanno; Gilles Puy; Yves Wiaux; Ruud B van Heeswijk; Davide Piccini; Matthias Stuber
Journal:  PLoS One       Date:  2014-08-29       Impact factor: 3.240

  6 in total