Literature DB >> 15507908

Distortion of disposable plastic stock trays when used with putty vinyl polysiloxane impression materials.

George C Cho1, Winston W L Chee.   

Abstract

STATEMENT OF PROBLEM: Impressions are made using high-viscosity putty vinyl polysiloxane impression materials in conjunction with disposable plastic stock trays. The impression materials have been shown to be dimensionally stable. However, it remains unclear if the disposable plastic stock trays are rigid enough to resist deformation thus yielding potentially unreliable results.
PURPOSE: This study evaluated the rigidity and ability to resist deformation of 6 commercially available disposable plastic stock trays and 1 metal stock tray when used in conjunction with a high-viscosity vinyl polysiloxane impression material.
MATERIAL AND METHODS: Ten impressions were made with 1 putty vinyl polysiloxane material (Reprosil Putty) using each of the 6 tested disposable plastic stock trays, Sani-Trays (perforated), Sani-Trays (nonperforated), COE Disposable Spacer Tray (perforated), COE Disposable Spacer Tray (nonperforated), Bosworth Tray-Aways (perforated), Track-it Trays (perforated), and 1 metal stock tray (nonperforated), Cadco Dental Products, as a control on a mandibular plastic model. The dimensions of the tray in cross section at the mandibular right first molar area were measured before, during, and after the impression procedures with an electronic digital caliper. The cross-arch dimensions of the tray were measured at similar intervals. One examiner made all measurements and each measurement was repeatable within +/-0.01 mm. A split plot repeated measures analysis of variance (ANOVA) was performed and 2-sided P -values were calculated (alpha=.05).
RESULTS: The results indicated that the disposable plastic trays tested were not sufficiently rigid to resist deformation when used with very high-viscosity putty material. Metal stock trays showed significantly less change in cross-arch dimension than plastic trays (F(1.68)=11.25, P =.001). Metal stock trays also showed significantly less change in cross-sectional arch dimension than plastic trays (F(1.68)=15.15, P<.001).
CONCLUSION: When disposable plastic stock trays were tested in conjunction with very high-viscosity impression materials there was distortion of the tray both across the arch and in cross section.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15507908     DOI: 10.1016/j.prosdent.2004.07.020

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; David R Louis; Mark S Litaker; Helena M Minyé; Thomas Oates; Valeria V Gordan; Don G Marshall; Cyril Meyerowitz; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2017-01-11       Impact factor: 2.752

2.  A Comparative Evaluation of Accuracy of the Dies Affected by Tray Type, Material Viscosity, and Pouring Sequence of Dual and Single Arch Impressions- An In vitro Study.

Authors:  Poonam R Kulkarni; Rahul S Kulkarni; Rupal J Shah; Rahul Chhajlani; Bhuwan Saklecha; Kavita Maru
Journal:  J Clin Diagn Res       Date:  2017-04-01

3.  Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization: a double-blinded, randomized clinical trial.

Authors:  Danush Ahrberg; Hans Christoph Lauer; Martin Ahrberg; Paul Weigl
Journal:  Clin Oral Investig       Date:  2015-06-14       Impact factor: 3.573

Review 4.  A Paradigm shift in the concept for making dental impressions.

Authors:  Sanjna Nayar; R Mahadevan
Journal:  J Pharm Bioallied Sci       Date:  2015-04

5.  In Vitro Comparative Evaluation of Different Types of Impression Trays and Impression Materials on the Accuracy of Open Tray Implant Impressions: A Pilot Study.

Authors:  Sonam Gupta; Aparna Ichalangod Narayan; Dhanasekar Balakrishnan
Journal:  Int J Dent       Date:  2017-02-27

6.  Accuracy of Implant Position Transfer and Surface Detail Reproduction with Different Impression Materials and Techniques.

Authors:  Marzieh Alikhasi; Hakimeh Siadat; Elaheh Beyabanaki; Mohammad Javad Kharazifard
Journal:  J Dent (Tehran)       Date:  2015-10