Literature DB >> 15506600

Screening for glaucoma in a general population with the non-mydriatic fundus camera and the frequency doubling perimeter.

M Detry-Morel1, T Zeyen, P Kestelyn, J Collignon, M Goethals.   

Abstract

PURPOSE: To evaluate the usefulness of non-mydriatic fundus camera (NMFu-camera) and frequency doubling perimeter (FDP) for detecting glaucoma in a general population.
METHODS: This prospective observational multicenter study consisted in screening for glaucoma in the populations of three Belgian cities. Intraocular pressure (IOP) was measured with non-contact pneumo-tonometer (NCT) and applanation tonometry (AT) if NCT IOP was > or = 17 mmHg. Visual field was screened with FDP (C-20-5) and digitized optic disc photographs (ODPs) were taken with NMFu-camera. FDP was considered abnormal if at least one defective point was found. ODPs were graded as normal or glaucomatous by consensus of three glaucoma specialists. Optic disc and visual field results were matched per eye. Subjects with known ocular hypertension and/or treated primary open angle glaucoma were excluded from the analysis.
RESULTS: A total of 1620 subjects were included in the study. Their mean age was 63.2 years. AT IOP was > 21 mmHg in 8.2%. A total of 98.1% of ODPs could be interpreted. Glaucomatous optic discs were detected in 3.5% of the subjects. In this group only 24% had an AT IOP > or = 22 mmHg. FDP was abnormal in 44.5%. The sensitivity and specificity of FDP to identify patients with an optic disc graded as glaucomatous were 58.6% and 64.3% respectively.
CONCLUSIONS: The combined use of the NMFu-camera and the FDP is a feasible method for an initial glaucoma mass screening. NMFu-camera may be a useful and quick method to screen for glaucomatous damage in a community. FDP in screening strategy was revealed to be not sensitive enough when setting the cut-off value at one defective test location. IOP measurements were confirmed to be a poor tool to detect glaucomatous damage.

Entities:  

Mesh:

Year:  2004        PMID: 15506600     DOI: 10.1177/112067210401400505

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  12 in total

Review 1.  A comprehensive review of diagnostic imaging technologies to evaluate the retina and the optic disk.

Authors:  Asima Bajwa; Rabia Aman; Ashvini K Reddy
Journal:  Int Ophthalmol       Date:  2015-06-05       Impact factor: 2.031

2.  Glaucoma detection with damato multifixation campimetry online.

Authors:  A S Olsen; M Alberti; L Serup; M la Cour; B Damato; M Kolko
Journal:  Eye (Lond)       Date:  2016-03-18       Impact factor: 3.775

3.  [Ophthalmic disease in diabetes mellitus: management from primary health care].

Authors:  María José Sender Palacios; María Vernet Vernet; Miguel Maseras Bové; Antoni Salvador Playà; Laia Pascual Batlle; Juan Carlos Ondategui Parra; Esther Jovell Fernández
Journal:  Aten Primaria       Date:  2010-04-07       Impact factor: 1.137

4.  Incidence of cilioretinal arteries in Chinese Han population.

Authors:  Lei Liu; Li-Min Liu; Lei Chen
Journal:  Int J Ophthalmol       Date:  2011-06-18       Impact factor: 1.779

5.  The papilla as screening parameter for early diagnosis of glaucoma.

Authors:  Georg Michelson; Simone Wärntges; Joachim Hornegger; Berthold Lausen
Journal:  Dtsch Arztebl Int       Date:  2008-08-25       Impact factor: 5.594

6.  The East London glaucoma prediction score: web-based validation of glaucoma risk screening tool.

Authors:  Cook Stephen; Longo-Mbenza Benjamin
Journal:  Int J Ophthalmol       Date:  2013-02-18       Impact factor: 1.779

7.  Prevalence and determinants of glaucoma in citizens of qatar aged 40 years or older: a community-based survey.

Authors:  Fatma A Al-Mansouri; Aida Kanaan; Hamad Gamra; Rajiv Khandekar; Shakeel P Hashim; Omar Al Qahtani; Mohd Farouk Ahmed
Journal:  Middle East Afr J Ophthalmol       Date:  2011-04

8.  Comparison of glaucoma patients referred by glaucoma screening versus referral from primary eye clinic.

Authors:  Yong Ju Song; Yong Woo Kim; Ki Ho Park; Young Kook Kim; Hyuk Jin Choi; Jin Wook Jeoung
Journal:  PLoS One       Date:  2019-01-10       Impact factor: 3.240

9.  Impact of illumination spectrum and eye pigmentation on image quality from a fundus camera using transscleral illumination.

Authors:  Alexey Stepanov; Jostein Thorstensen; Jon Tschudi
Journal:  J Biomed Opt       Date:  2021-07       Impact factor: 3.170

10.  Diagnostic Accuracy of Nonmydriatic Fundus Photography for the Detection of Glaucoma in Diabetic Patients.

Authors:  Francisco J Muñoz-Negrete; Inés Contreras; Noelia Oblanca; M Dolores Pinazo-Durán; Gema Rebolleda
Journal:  Biomed Res Int       Date:  2015-10-18       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.