Literature DB >> 15504115

Comparison of a new heparin-coated dense membrane lung with nonheparin-coated dense membrane lung for prolonged extracorporeal lung assist in goats.

Keisuke Ichinose1, Taisuke Okamoto, Hironari Tanimoto, Atsushi Yoshitake, Masafumi Tashiro, Yuji Sakanashi, Katsuyuki Kuwana, Koichiro Tahara, Masahiro Kamiya, Hidenori Terasaki.   

Abstract

Thrombosis and bleeding are major complications in cases of prolonged extracorporeal lung assist (ECLA) with an artificial-membrane lung. Antithrombogenic treatment of the artificial-membrane oxygenator and circuits is indispensable for safe ECLA. The efficacy of a new heparin-coated membrane lung with minimal systemic heparinization was evaluated for 7 days and compared with a nonheparin-coated membrane lung in goats. The animals were randomly assigned to either the heparin-coated membrane group (HM group, n = 5) or nonheparin-coated membrane group (NHM group, n = 5). Activated coagulation time (ACT) during ECLA was controlled to below 150 s in the HM group, and to near 200 s in the NHM group. All goats in the HM group were sustained on ECLA for 7 days, but two goats in the NHM group died on the 4th and 6th days, respectively. The mean systemic administration rate of heparin during ECLA was 22.4 +/- 4.4 U/kg/h in the HM group and 39.0 +/- 10.0 U/kg/h in the NHM group. There was a significant difference between the two groups (P < 0.05). The oxygen transfer rate, the Pco(2) difference, the perfusion resistance, and platelet counts showed no significant changes. There was no plasma leakage from the artificial lung. Although several clots were observed in the stagnant areas of the artificial lung, they did not lead to deterioration of the function of the artificial lung. The excellent antithrombogenicity, gas exchange ability, and durability of this new artificial lung with circuits might contribute to successful prolonged ECLA with minimal systemic heparinization.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15504115     DOI: 10.1111/j.1525-1594.2004.07312.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  2 in total

1.  Computational study of the blood flow in three types of 3D hollow fiber membrane bundles.

Authors:  Jiafeng Zhang; Xiaobing Chen; Jun Ding; Katharine H Fraser; M Ertan Taskin; Bartley P Griffith; Zhongjun J Wu
Journal:  J Biomech Eng       Date:  2013-12       Impact factor: 2.097

2.  Establishment and evaluation of a rat model of extracorporeal membrane oxygenation (ECMO) thrombosis using a 3D-printed mock-oxygenator.

Authors:  Nao Umei; Angela Lai; Jennifer Miller; Suji Shin; Kalliope Roberts; Saif Ai Qatarneh; Shingo Ichiba; Atsuhiro Sakamoto; Keith E Cook
Journal:  J Transl Med       Date:  2021-04-28       Impact factor: 5.531

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.