Literature DB >> 15503976

Automatic estimation of endothelium cell density in donor corneas by means of fourier analysis.

M Foracchia1, A Ruggeri.   

Abstract

One of the main clinical parameters expressing the health of a cornea is the cell density of its endothelium. This information is particularly important in an eye bank environment, where donor corneas are screened to assess their suitability as a human graft. Endothelium cell density is conventionally estimated by a long, tedious and error-prone manual counting procedure, performed by cornea experts on specimen images observed through an optical microscope. An alternative solution is proposed: a computer program that provides automatic estimation of cell density in donor corneas by analysing the spatial frequencies contained in the image. A circular band in the 2D discrete Fourier transform of the image is shown to contain the relevant information about the cell density. A system for extracting from this spatial frequency information an estimate of the cell density has been developed. A clinical evaluation of the proposed technique was performed on 18 corneas, where the densities provided by the proposed technique were compared with those manually obtained by two experts. The results showed an average percentage difference of 3% (maximum 19%), a value well within the measured inter-expert range of variability. The proposed automatic procedure confirmed its ability to estimate correctly corneal endothelium cell density.

Entities:  

Mesh:

Year:  2004        PMID: 15503976     DOI: 10.1007/bf02347557

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Automated tri-image analysis of stored corneal endothelium.

Authors:  P Gain; G Thuret; L Kodjikian; Y Gavet; P H Turc; C Theillere; S Acquart; J C Le Petit; J Maugery; L Campos
Journal:  Br J Ophthalmol       Date:  2002-07       Impact factor: 4.638

2.  Predicting endothelial cell loss and long-term corneal graft survival.

Authors:  W John Armitage; Andrew D Dick; William M Bourne
Journal:  Invest Ophthalmol Vis Sci       Date:  2003-08       Impact factor: 4.799

3.  Comparison of corneal endothelial image analysis by Konan SP8000 noncontact and Bio-Optics Bambi systems.

Authors:  B A Benetz; E Diaconu; S J Bowlin; S S Oak; R A Laing; J H Lass
Journal:  Cornea       Date:  1999-01       Impact factor: 2.651

4.  Fourier transform analysis of human corneal endothelial specular photomicrographs.

Authors:  F W Fitzke; B R Masters; R J Buckley; L Speedwell
Journal:  Exp Eye Res       Date:  1997-08       Impact factor: 3.467

5.  Automated video image morphometry of the corneal endothelium.

Authors:  J V Siertsema; M Landesz; H van den Brom; G van Rij
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

6.  Automated in vivo and online morphometry of human corneal endothelium.

Authors:  G Corkidi; J Marquez; R Usisima; R Toledo; J Valdéz; E Graue
Journal:  Med Biol Eng Comput       Date:  1993-07       Impact factor: 2.602

7.  Automated analysis of wide-field specular photomicrographs.

Authors:  L W Hirst; R E Sterner; D G Grant
Journal:  Cornea       Date:  1984       Impact factor: 2.651

8.  Automated morphometric analysis of corneal endothelial cells.

Authors:  J M Lester; J L McFarland; S E Bursell; R A Laing; J F Brenner
Journal:  Invest Ophthalmol Vis Sci       Date:  1981-03       Impact factor: 4.799

9.  Automated digital image analysis of organ culture preserved donor corneas.

Authors:  T Barisani-Asenbauer; I Baumgartner; G Grabner; M Stur
Journal:  Ophthalmic Res       Date:  1993       Impact factor: 2.892

View more
  3 in total

1.  Application of higher-order spectra for automated grading of diabetic maculopathy.

Authors:  Muthu Rama Krishnan Mookiah; U Rajendra Acharya; Vinod Chandran; Roshan Joy Martis; Jen Hong Tan; Joel E W Koh; Chua Kuang Chua; Louis Tong; Augustinus Laude
Journal:  Med Biol Eng Comput       Date:  2015-04-18       Impact factor: 2.602

2.  In vivo corneal endothelium imaging using ultrahigh resolution OCT.

Authors:  Xinwen Yao; Kavya Devarajan; René M Werkmeister; Valentin Aranha Dos Santos; Marcus Ang; Anthony Kuo; Damon W K Wong; Jacqueline Chua; Bingyao Tan; Veluchamy Amutha Barathi; Leopold Schmetterer
Journal:  Biomed Opt Express       Date:  2019-10-11       Impact factor: 3.732

3.  Fully automatic evaluation of the corneal endothelium from in vivo confocal microscopy.

Authors:  Bettina Selig; Koenraad A Vermeer; Bernd Rieger; Toine Hillenaar; Cris L Luengo Hendriks
Journal:  BMC Med Imaging       Date:  2015-04-26       Impact factor: 1.930

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.