Literature DB >> 15503239

[Interobserver variation of the sonographic diagnosis of orbital floor fractures and fractures of the infraorbital margin].

S Jank1, M Deibl, H Strobl, A Oberrauch, A Nicasi, M Missmann, G Bodner.   

Abstract

PURPOSE: The aim of the study was to evaluate the interobserver variation of the ultrasound diagnosis of orbital floor fractures and fractures of the infraorbital rim.
MATERIAL AND METHODS: A total of 25 patients with a clinical diagnosis of an orbital trauma were investigated prospectively by computed tomography (CT) and ultrasonography (US). Inter-observer variation was calculated using the lambda coefficient (lambda). The US images were reassessed by two inexperienced investigators.
RESULTS: The lambda value for the US investigation of the orbital floor showed poor reliability comparing the US findings with the results of the re-investigators. The comparison between the two re-investigators showed a good reliability for the US evaluation of the orbital floor. The lambda for the US investigation of the infraorbital margin showed a good reliability comparing the US findings with the results of the both re-investigators. The comparison of the two re-investigators showed a good reliability as well.
CONCLUSION: Ultrasound is not yet an alternative method for the evaluation of orbital floor fractures and fractures of the infraorbital margin. To replace CT which is accepted as the current gold standard, further studies have to be done to reach a better diagnostic quality of the method and to achieve a better calibration of the investigations.

Entities:  

Mesh:

Year:  2004        PMID: 15503239     DOI: 10.1007/s10006-004-0571-7

Source DB:  PubMed          Journal:  Mund Kiefer Gesichtschir        ISSN: 1432-9417


  26 in total

Review 1.  [The three-dimensional spiral scanner and volume rendering technique: importance in craniofacial traumatology and reconstructive surgery].

Authors:  H Bénateau; E Chevallier; M Hamon; E Edy; R Keswani; D Labbé; G Schmutz; J F Compère
Journal:  Rev Stomatol Chir Maxillofac       Date:  2002-09

2.  Ultrasound versus computed tomography in the imaging of orbital floor fractures.

Authors:  Siegfried Jank; Rüdiger Emshoff; Monika Etzelsdorfer; Heinrich Strobl; Alessandro Nicasi; Burghard Norer
Journal:  J Oral Maxillofac Surg       Date:  2004-02       Impact factor: 1.895

3.  A comparison of radiographic treatment methods for evaluation of the orbit.

Authors:  N Berardo; S G Leban; F A Williams
Journal:  J Oral Maxillofac Surg       Date:  1988-10       Impact factor: 1.895

4.  [Ultrasonic diagnosis of fractures of the bony orbit].

Authors:  R Rochels
Journal:  Fortschr Kiefer Gesichtschir       Date:  1987

5.  Subtle diagnostic markers of orbital floor blow-out fracture on coronal CT scan.

Authors:  J M Rowe-Jones; E J Adam; V Moore-Gillon
Journal:  J Laryngol Otol       Date:  1993-02       Impact factor: 1.469

6.  Orbital fracture evaluation by coronal computed tomography.

Authors:  A S Grove; R Tadmor; P F New; K J momose
Journal:  Am J Ophthalmol       Date:  1978-05       Impact factor: 5.258

7.  [Conventional radiology and computed tomography in facial fractures].

Authors:  H Dorobisz; E Voegeli; N Hardt
Journal:  Rontgenblatter       Date:  1983-12

8.  [Ultrasound diagnosis of orbital floor fractures: an alternative to computerized tomography?].

Authors:  M Klinger; J Danter; R Siegert
Journal:  Laryngorhinootologie       Date:  1996-04       Impact factor: 1.057

9.  Direct oblique sagittal CT of orbital wall fractures.

Authors:  J B Ball
Journal:  AJR Am J Roentgenol       Date:  1987-03       Impact factor: 3.959

10.  The diagnostic value of ultrasonography in the detection of orbital floor fractures with a curved array transducer.

Authors:  S Jank; R Emshoff; M Etzelsdorfer; H Strobl; A Nicasi; B Norer
Journal:  Int J Oral Maxillofac Surg       Date:  2004-01       Impact factor: 2.789

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.