Literature DB >> 14690654

The diagnostic value of ultrasonography in the detection of orbital floor fractures with a curved array transducer.

S Jank1, R Emshoff, M Etzelsdorfer, H Strobl, A Nicasi, B Norer.   

Abstract

The aim of the study was to investigate the diagnostic value of ultrasonography (US) in orbital floor fractures and orbital rim fractures with a curved array scanner. Over a period of 10 months, 60 patients with an orbital trauma have been investigated. Orbital trauma was defined by clinical and ophthalmologic investigation. Computed tomography (CT) was used as the reference method to evaluate the diagnostic value of US in the determination of an orbital floor fracture and was performed by a well-experienced radiologist. Coronal and sagittal images were made. The US investigation was performed with a 7.5 MHz curved array transducer.The US investigation of the infraorbital rim showed a sensitivity of 94% and a specificity of 92% with a diagnostic accuracy of 92%. The positive predictive value (PPV) reached 91% and the negative predictive value (NPV) reached 92%, while the US investigation of the orbital floor showed a sensitivity of 95% and a specificity of 100% with a diagnostic accuracy of 98%. PPV reached 100% and NPV reached 77%. Ultrasonography is a cost-effective and widely available method without disadvantages such as radiation exposure. The results in the current study imply that ultrasonography can be used as an alternative method in the investigation of orbital floor fractures.

Entities:  

Mesh:

Year:  2004        PMID: 14690654     DOI: 10.1054/ijom.2003.0456

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  4 in total

1.  Comparison of ultrasonography with computed tomography in the diagnosis of nasal bone fractures.

Authors:  R Javadrashid; M Khatoonabad; N Shams; F Esmaeili; H Jabbari Khamnei
Journal:  Dentomaxillofac Radiol       Date:  2011-12       Impact factor: 2.419

2.  [Interobserver variation of the sonographic diagnosis of orbital floor fractures and fractures of the infraorbital margin].

Authors:  S Jank; M Deibl; H Strobl; A Oberrauch; A Nicasi; M Missmann; G Bodner
Journal:  Mund Kiefer Gesichtschir       Date:  2004-10-21

3.  A comparable study of the diagnostic performance of orbital ultrasonography and CBCT in patients with suspected orbital floor fractures.

Authors:  Masoumeh Johari; Mohammad Ali Ghavimi; Hediyeh Mahmoudian; Reza Javadrashid; Simin Mirakhor Samani; Daniel F Fouladi
Journal:  Dentomaxillofac Radiol       Date:  2016-05-04       Impact factor: 2.419

Review 4.  Diagnostic Accuracy of Ultrasonography for the Assessment of Maxillofacial Fractures: A Meta-analysis.

Authors:  Srikanth Gadicherla; Kalyana-Chakravarthy Pentapati; Nasrullah Rustaqi; Anupam Singh; Komal Smriti
Journal:  J Int Soc Prev Community Dent       Date:  2021-09-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.