Continuous ventilation technique for laryngeal mask airway (LMA) removal after fiberoptic intubation in children.

Markus Weiss1, Andreas C Gerber, Achim Schmitz.   

Abstract

BACKGROUND: Fiberoptic tracheal intubation through the laryngeal mask airway (LMA) is a simple technique to establish a safe airway in neonates and infants with a difficult airway. The technique, however, is complicated by the removal of the laryngeal mask from the patient's mouth because of the similarity in length of the LMA and the tracheal tube.
METHODS: Several solutions have been presented to stabilize the tracheal tube within the trachea during withdrawal of the LMA. With all these techniques ventilation of the patient is interrupted.
RESULTS: We present a modified technique, using a double tube assembly, which allows uninterrupted ventilation of the patient during withdrawal of the LMA from the patient's mouth.
CONCLUSIONS: The technique is simple and safe, can be performed without hurry and carries potential advantages for neonates and children with limited cardiorespiratory reserve.

Entities:  

Mesh:

Year:  2004        PMID: 15500494     DOI: 10.1111/j.1460-9592.2004.01354.x

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  11 in total

1.  Supraglottic jet oxygenation and ventilation-assisted fibre-optic bronchoscope intubation in patients with difficult airways.

Authors:  Caineng Wu; Jianqi Wei; Qingyun Cen; Xuefan Sha; Qingxiang Cai; Wuhua Ma; Ying Cao
Journal:  Intern Emerg Med       Date:  2016-09-14       Impact factor: 3.397

2.  [Distance from the laryngeal mask grip to endotracheal tube tip. A crucial point during fiberoptic intubation in children].

Authors:  J Mauch; T Haas; M Weiss
Journal:  Anaesthesist       Date:  2012-02-23       Impact factor: 1.041

3.  [Fibre optic-assisted endotracheal intubation through the laryngeal mask in children].

Authors:  M Weiss; J Mauch; K Becke; J Schmidt; M Jöhr
Journal:  Anaesthesist       Date:  2009-07       Impact factor: 1.041

4.  Fiberoptic Intubation Using LMA as A Conduit and Cook Airway Catheter as An Exchanger in A Case of Tessier 7 Facial Cleft Syndrome.

Authors:  D Dasgupta; Anand Jain; Vaibhavi Baxi; A Parab; A Budhakar
Journal:  Indian J Anaesth       Date:  2009-04

5.  Tracheal Intubation with Aura-i and aScope-2: How to Minimize Apnea Time in an Unpredicted Difficult Airway.

Authors:  Vittorio Pavoni; Valentina Froio; Alessandra Nella; Martina Simonelli; Lara Gianesello; Andrew Horton; Luca Malino; Massimo Micaglio
Journal:  Case Rep Anesthesiol       Date:  2015-01-06

6.  Comparison of the air-Q intubating laryngeal airway and the cobra perilaryngeal airway as conduits for fiber optic-guided intubation in pediatric patients.

Authors:  Karim K Girgis; Maha M I Youssef; Nashwa S ElZayyat
Journal:  Saudi J Anaesth       Date:  2014-10

7.  Conversion of I-gel to definitive airway in a cervical immobilized manikin: Aintree intubation catheter vs long endotracheal tube.

Authors:  Yun Jeong Chae; Heirim Lee; Bokyeong Jun; In Kyong Yi
Journal:  BMC Anesthesiol       Date:  2020-06-18       Impact factor: 2.217

8.  Comparison of oral fiberoptic intubation via a modified guedel airway or a laryngeal mask airway in infants and children.

Authors:  Elsa Varghese; R Nagaraj; R Shwethapriya
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2013-01

9.  Ambu AuraOnce versus i-gel laryngeal mask airway in infants and children undergoing surgical procedures. A randomized controlled trial.

Authors:  Abdulrahman M Alzahem; Mansoor Aqil; Tariq A Alzahrani; Ayman H Aljazaeri
Journal:  Saudi Med J       Date:  2017-05       Impact factor: 1.484

10.  Dimensional compatibility and limitations of tracheal intubation through supraglottic airway devices: a mannequin-based in vitro study.

Authors:  Berthold Moser; Michael Kemper; Maren Kleine-Brueggeney; Lukas Gasteiger; Markus Weiss
Journal:  Can J Anaesth       Date:  2021-05-20       Impact factor: 5.063

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.