Ionization chamber-based reference dosimetry of intensity modulated radiation beams.

Hugo Bouchard1, Jan Seuntjens.   

Abstract

The present paper addresses reference dose measurements using thimble ionization chambers for quality assurance in IMRT fields. In these radiation fields, detector fluence perturbation effects invalidate the application of open-field dosimetry protocol data for the derivation of absorbed dose to water from ionization chamber measurements. We define a correction factor C(Q)IMRT to correct the absorbed dose to water calibration coefficient N(D, w)Q for fluence perturbation effects in individual segments of an IMRT delivery and developed a calculation method to evaluate the factor. The method consists of precalculating, using accurate Monte Carlo techniques, ionization chamber, type-dependent cavity air dose, and in-phantom dose to water at the reference point for zero-width pencil beams as a function of position of the pencil beams impinging on the phantom surface. These precalculated kernels are convolved with the IMRT fluence distribution to arrive at the dose-to-water-dose-to-cavity air ratio [D(a)w (IMRT)] for IMRT fields and with a 10x10 cm2 open-field fluence to arrive at the same ratio D(a)w (Q) for the 10x10 cm2 reference field. The correction factor C(Q)IMRT is then calculated as the ratio of D(a)w (IMRT) and D(a)w (Q). The calculation method was experimentally validated and the magnitude of chamber correction factors in reference dose measurements in single static and dynamic IMRT fields was studied. The results show that, for thimble-type ionization chambers the correction factor in a single, realistic dynamic IMRT field can be of the order of 10% or more. We therefore propose that for accurate reference dosimetry of complete n-beam IMRT deliveries, ionization chamber fluence perturbation correction factors must explicitly be taken into account.

Entities:  

Mesh:

Year:  2004        PMID: 15487725     DOI: 10.1118/1.1781333

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  The change of response of ionization chambers in the penumbra and transmission regions: impact for IMRT verification.

Authors:  D González-Castaño; J Pena; F Sánchez-Doblado; G H Hartmann; F Gómez; A Leal
Journal:  Med Biol Eng Comput       Date:  2007-09-08       Impact factor: 2.602

2.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

3.  Beam data modeling of linear accelerators (linacs) through machine learning and its potential applications in fast and robust linac commissioning and quality assurance.

Authors:  Wei Zhao; Ishan Patil; Bin Han; Yong Yang; Lei Xing; Emil Schüler
Journal:  Radiother Oncol       Date:  2020-10-08       Impact factor: 6.280

4.  A method to improve fluence resolution derived from two-dimensional detector array measurements for patient-specific IMRT verification using the information collected in dynalog files.

Authors:  Juan Agustin Calama Santiago; Miguel Angel Infante Utrilla; Maria Elisa Lavado Rodriguez
Journal:  J Med Phys       Date:  2015 Jan-Mar

5.  aSi-EPID transit signal calibration for dynamic beams: a needful step for the IMRT in vivo dosimetry.

Authors:  Francesca Greco; Angelo Piermattei; Luigi Azario; Lorenzo Placidi; Savino Cilla; Rocchina Caivano; Vincenzo Fusco; Andrea Fidanzio
Journal:  Med Biol Eng Comput       Date:  2013-07-09       Impact factor: 2.602

6.  Radiation dose verification using real tissue phantom in modern radiotherapy techniques.

Authors:  Om Prakash Gurjar; S P Mishra; Virendra Bhandari; Pankaj Pathak; Prapti Patel; Garima Shrivastav
Journal:  J Med Phys       Date:  2014-01

7.  Clinical implementation and error sensitivity of a 3D quality assurance protocol for prostate and thoracic IMRT.

Authors:  Gueorgui Gueorguiev; Christopher Cotter; Julie Catherine Turcotte; Bruce Crawford; Gregory Sharp; Mufeed Mah'D
Journal:  J Appl Clin Med Phys       Date:  2015-09-08       Impact factor: 2.102

8.  Reference dosimetry using radiochromic film.

Authors:  Frédéric Girard; Hugo Bouchard; Frédéric Lacroix
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

9.  Characterization of cylindrical ionization chambers for patient specific IMRT QA.

Authors:  Danielle Fraser; William Parker; Jan Seuntjens
Journal:  J Appl Clin Med Phys       Date:  2009-09-30       Impact factor: 2.102

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.