Patient dose optimization in plain radiography based on standard exposure factors.

J George1, J P Eatough, P J Mountford, C J Koller, J Oxtoby, G Frain.   

Abstract

A computational technique for assessing patient dose in plain radiography is described allowing a large number of examinations to be assessed and enabling dose optimization to be promoted. Entrance surface dose (ESD) was calculated for more than 1500 standard exposure settings in an initial dose assessment. Validation of the technique showed good agreement with thermoluminescent dosimetry and showed broad agreement between the standard exposures and the exposure settings used in practice. The dose assessment was repeated 18 months later using the same techniques for almost 2000 standard exposure settings. In both cases, calculated doses showed good compliance with national diagnostic reference levels where available. Suggested investigation levels were established and set at twice the mean dose for each of 47 examinations. Radiology departments were encouraged to review and optimize doses exceeding these levels. The computed mean ESD in the review study was less than the corresponding value in the initial study in 37 of the 47 examinations. The dose reduction was attributable partly to equipment replacement, but primarily to optimization of exposure settings. The technique employed here provides a valid and cost effective method of complying with statutory requirements for the assessment of representative patient dose and is useful in assisting the ongoing process of dose optimization.

Entities:  

Mesh:

Year:  2004        PMID: 15482998     DOI: 10.1259/bjr/21484847

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  7 in total

1.  Normalizing Heterogeneous Medical Imaging Data to Measure the Impact of Radiation Dose.

Authors:  Luís A Bastião Silva; Luís S Ribeiro; Milton Santos; Nuno Neves; Dulce Francisco; Carlos Costa; José Luis Oliveira
Journal:  J Digit Imaging       Date:  2015-12       Impact factor: 4.056

2.  Size-specific dose estimates: Localizer or transverse abdominal computed tomography images?

Authors:  Sarvenaz Pourjabbar; Sarabjeet Singh; Atul Padole; Akshay Saini; Michael A Blake; Mannudeep K Kalra
Journal:  World J Radiol       Date:  2014-05-28

3.  Optimisation in general radiography.

Authors:  Cj Martin
Journal:  Biomed Imaging Interv J       Date:  2007-04-01

4.  Intensive care nurses' knowledge of radiation safety and their behaviors towards portable radiological examinations.

Authors:  Mansoor Dianati; Azita Zaheri; Hamid Reza Talari; Fateme Deris; Sara Rezaei
Journal:  Nurs Midwifery Stud       Date:  2014-12-29

5.  Optimization of patient radiation protection in pelvic X-ray examination in Ghana.

Authors:  Eric K Ofori; William K Antwi; Diane N Scutt; Matt Ward
Journal:  J Appl Clin Med Phys       Date:  2012-07-05       Impact factor: 2.102

6.  Exposure Levels of Adult Patients during Radiographic Examinations: Sinuses and Coastal Grill Cases at the Ngaoundere Regional Hospital, Cameroon.

Authors:  Guiswe Gnowe; Fouda H P Ekobena; Amvene J Mbo; Guena M Neossi
Journal:  Radiol Res Pract       Date:  2019-04-30

7.  Measurement of entrance surface dose on an anthropomorphic thorax phantom using a miniature fiber-optic dosimeter.

Authors:  Wook Jae Yoo; Sang Hun Shin; Dayeong Jeon; Seunghan Hong; Hyeok In Sim; Seon Geun Kim; Kyoung Won Jang; Seunghyun Cho; Won Sik Youn; Bongsoo Lee
Journal:  Sensors (Basel)       Date:  2014-04-01       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.