AIM: The clinical value of combined XCT/SPECT technology in a single device in patients undergoing (123)I-MIBG scintigraphy was analyzed. METHODS: 31 patients (19 men, 12 women; mean age 55 years, range: 31-79 years) demonstrating focal accumulation in planar (123)I-MIBG scan were further investigated with a double headed gamma camera with an X-ray tomograph mounted on the same gantry (GE Medical Systems, Millennium VG with Hawkeye, Milwaukee, USA) for anatomical definition of the focal (123)I-MIBG uptake. The patients were referred to (123)I-MIBG scintigraphy because of biochemically (81%) and/or clinically (19%) suspected pheochromocytoma. RESULTS: In 23 out of 31 patients (74%) the fused images demonstrated physiological accumulation (i. e. intestinal, renal) of (123)I-MIBG. In two patients (6%) suspected adrenal MIBG-accumulation was caused by inhomogeneous liver uptake. In two patients (6%) focal abdominal accumulation was correctly localised in the adrenal glands. Furthermore, the differentiation of bone metastasis from a local recurrence for phaeochromocytoma was accurately possible for two patients (6%). Adrenal lesions mimicking liver foci were correctly localised in the remaining two patients (6%). CONCLUSION: Our study demonstrates the clinical value of XCT/SPECT in a single device in patients demonstrating focal (123)I-MIBG uptake in planar scintigraphy. The combined XCT/SPECT technology provides a higher diagnostic accuracy.
AIM: The clinical value of combined XCT/SPECT technology in a single device in patients undergoing (123)I-MIBG scintigraphy was analyzed. METHODS: 31 patients (19 men, 12 women; mean age 55 years, range: 31-79 years) demonstrating focal accumulation in planar (123)I-MIBG scan were further investigated with a double headed gamma camera with an X-ray tomograph mounted on the same gantry (GE Medical Systems, Millennium VG with Hawkeye, Milwaukee, USA) for anatomical definition of the focal (123)I-MIBG uptake. The patients were referred to (123)I-MIBG scintigraphy because of biochemically (81%) and/or clinically (19%) suspected pheochromocytoma. RESULTS: In 23 out of 31 patients (74%) the fused images demonstrated physiological accumulation (i. e. intestinal, renal) of (123)I-MIBG. In two patients (6%) suspected adrenal MIBG-accumulation was caused by inhomogeneous liver uptake. In two patients (6%) focal abdominal accumulation was correctly localised in the adrenal glands. Furthermore, the differentiation of bone metastasis from a local recurrence for phaeochromocytoma was accurately possible for two patients (6%). Adrenal lesions mimicking liver foci were correctly localised in the remaining two patients (6%). CONCLUSION: Our study demonstrates the clinical value of XCT/SPECT in a single device in patients demonstrating focal (123)I-MIBG uptake in planar scintigraphy. The combined XCT/SPECT technology provides a higher diagnostic accuracy.
Authors: Giuliano Mariani; Laura Bruselli; Torsten Kuwert; Edmund E Kim; Albert Flotats; Ora Israel; Maurizio Dondi; Naoyuki Watanabe Journal: Eur J Nucl Med Mol Imaging Date: 2010-02-25 Impact factor: 9.236
Authors: Michail Plotkin; Reinhard Wurm; Julia Eisenacher; Katarzyna Szerewicz; Roger Michel; Lorenz Schlenger; Maciej Pech; Timm Denecke; David Kuczer; Annet Bischoff; Roland Felix; Holger Amthauer Journal: Eur Radiol Date: 2005-06-28 Impact factor: 5.315
Authors: P Castaldi; V Rufini; G Treglia; I Bruno; G Perotti; G Stifano; B Barbaro; A Giordano Journal: Radiol Med Date: 2008-09-16 Impact factor: 3.469
Authors: Rodolfo Núñez; William D Erwin; Richard E Wendt; Anne Stachowiak; Martha Mar; Donna Stevens; John E Madewell; Henry W Yeung; Homer A Macapinlac Journal: Mol Imaging Biol Date: 2010-01-05 Impact factor: 3.488