Literature DB >> 23990144

SPECT/CT and tumour imaging.

Gad Abikhzer1, Zohar Keidar.   

Abstract

Scintigraphic techniques are sensitive imaging modalities in the diagnosis and follow-up of cancer patients providing the functional and metabolic activity characteristics of the tumour. Hybrid SPECT/CT improves the diagnostic accuracy of these well-established imaging techniques by precise anatomical localization and characterization of morphological findings, differentiation between foci of physiological and pathological tracer uptake, resulting in a significant impact on patient management and more definitive interpretations. The use of SPECT/CT has been studied in a variety of applications in tumour imaging which are reviewed in this article. By combining functional and anatomical information in a single imaging session, SPECT/CT has become a one-stop cancer imaging modality.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23990144     DOI: 10.1007/s00259-013-2534-4

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  111 in total

1.  SPECT-CT for topographic mapping of sentinel lymph nodes prior to gamma probe-guided biopsy in head and neck squamous cell carcinoma.

Authors:  Arne Wagner; Kurt Schicho; Christoph Glaser; Georg Zettinig; Kaan Yerit; Susanne Lang; Clemens Klug; Thomas Leitha
Journal:  J Craniomaxillofac Surg       Date:  2004-12       Impact factor: 2.078

2.  ProstaScint (capromab pendetide) imaging using hybrid gamma camera-CT technology.

Authors:  Terence Z Wong; Timothy G Turkington; Thomas J Polascik; R Edward Coleman
Journal:  AJR Am J Roentgenol       Date:  2005-02       Impact factor: 3.959

3.  Sentinel lymph node mapping using SPECT-CT fusion imaging in patients with oral cavity squamous cell carcinoma.

Authors:  Harri Keski-Säntti; Sorjo Mätzke; Tomi Kauppinen; Jyrki Törnwall; Timo Atula
Journal:  Eur Arch Otorhinolaryngol       Date:  2006-07-08       Impact factor: 2.503

4.  Lymphoscintigraphy for sentinel node mapping using a hybrid single photon emission CT (SPECT)/CT system in oral cavity squamous cell carcinoma.

Authors:  Avi Khafif; Shlomo Schneebaum; Dan M Fliss; Hedva Lerman; U Metser; Rami Ben-Yosef; Ziv Gil; Leonor Reider-Trejo; Livshitz Genadi; Einat Even-Sapir
Journal:  Head Neck       Date:  2006-10       Impact factor: 3.147

5.  The additional value of SPECT/CT in lymphatic mapping in breast cancer and melanoma.

Authors:  Iris M C van der Ploeg; Renato A Valdés Olmos; Omgo E Nieweg; Emiel J Th Rutgers; Bin B R Kroon; Cornelis A Hoefnagel
Journal:  J Nucl Med       Date:  2007-10-17       Impact factor: 10.057

6.  Efficacy of ⁹⁹mTc-sestamibi SPECT/CT for minimally invasive parathyroidectomy: comparative study with ⁹⁹mTc-sestamibi scintigraphy, SPECT, US and CT.

Authors:  Yong-Il Kim; Young Ho Jung; Ki Tae Hwang; Ho-Young Lee
Journal:  Ann Nucl Med       Date:  2012-08-09       Impact factor: 2.668

7.  111In-pentetreotide scintigraphy: procedure guidelines for tumour imaging.

Authors:  Emilio Bombardieri; Valentina Ambrosini; Cumali Aktolun; Richard P Baum; Angelica Bishof-Delaloye; Silvana Del Vecchio; Lorenzo Maffioli; Luc Mortelmans; Wim Oyen; Giovanna Pepe; Arturo Chiti
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-07       Impact factor: 9.236

Review 8.  Somatostatin receptor scintigraphy with [111In-DTPA-D-Phe1]- and [123I-Tyr3]-octreotide: the Rotterdam experience with more than 1000 patients.

Authors:  E P Krenning; D J Kwekkeboom; W H Bakker; W A Breeman; P P Kooij; H Y Oei; M van Hagen; P T Postema; M de Jong; J C Reubi
Journal:  Eur J Nucl Med       Date:  1993-08

9.  Single photon emission computed tomography (SPECT) should be routinely performed for the detection of parathyroid abnormalities utilizing technetium-99m sestamibi parathyroid scintigraphy.

Authors:  Damita L Thomas; Twyla Bartel; Yusuf Menda; James Howe; Michael M Graham; Malik E Juweid
Journal:  Clin Nucl Med       Date:  2009-10       Impact factor: 7.794

10.  Accuracy of four-dimensional CT for the localization of abnormal parathyroid glands in patients with primary hyperparathyroidism.

Authors:  George J Hunter; Dawid Schellingerhout; Thinh H Vu; Nancy D Perrier; Leena M Hamberg
Journal:  Radiology       Date:  2012-07-12       Impact factor: 11.105

View more
  4 in total

1.  SPECT/CT workflow and imaging protocols.

Authors:  Catherine Beckers; Roland Hustinx
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-12-07       Impact factor: 9.236

2.  Combined SPECT/CT improves detection of initial bone invasion and determination of resection margins in squamous cell carcinoma of the head and neck compared to conventional imaging modalities.

Authors:  A Kolk; T Schuster; A Chlebowski; P Lange; K Scheidhauer; M Kesting; O Bissinger; M Schwaiger; J Dinges; J Weitz
Journal:  Eur J Nucl Med Mol Imaging       Date:  2014-02-27       Impact factor: 9.236

3.  The one-in-all diagnostic value of 99mTc-MDP bone scan combining with single-photon emission tomography (SPECT)/CT imaging in spinal osteoblastoma.

Authors:  Wenhui Ma; Zhiyong Quan; Jing Wang; Xiangdong Li; Guoquan Li
Journal:  J Orthop Surg Res       Date:  2020-05-24       Impact factor: 2.359

4.  Intravenous contrast-enhanced CT can be used for CT-based attenuation correction in clinical (111)In-octreotide SPECT/CT.

Authors:  Thomas Levin Klausen; Jann Mortensen; Robin de Nijs; Flemming Littrup Andersen; Liselotte Højgaard; Thomas Beyer; Søren Holm
Journal:  EJNMMI Phys       Date:  2015-02-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.