Literature DB >> 15480038

Dynamic breast magnetic resonance imaging. Effect of changing the region of interest on early enhancement using 2D and 3D techniques.

Francesco Sardanelli1, Alfonso Fausto, Andrea Iozzelli, Giuseppe Rescinito, Massimo Calabrese.   

Abstract

OBJECTIVE: To assess the effect of changing the region of interest (ROI) on early enhancement (EE) in dynamic breast magnetic resonance (MR) imaging.
METHODS: We evaluated retrospectively 102 breast lesions: 54 lesions (33 malignancies and 21 benignancies) studied with 2D and 48 lesions (30 and 18, respectively) with 3D gradient-echo dynamic technique (contrast dose 0.1 mmol/kg). Each lesion was postprocessed using 3 different regions of interest (ROIs): small circular ROI on maximal enhancement (SCR); large circular ROI within the lesion (LCR); and irregular ROI by manual contouring (IRR). EE was classified as benign (< or = 50%), uncertain (51-89%), or malignant (> or = 90%).
RESULTS: With 2D, the uncertain EEs were 17% for both SCR and LCR, 33% for IRR (P = 0.008); with 3D, the uncertain EEs were 4%, 15%, and 13%, respectively (SCR versus LCR, P = 0.063). More uncertain EEs were obtained with 2D (17-33%) than with 3D (4-15%), significantly for SCR (P = 0.043) and IRR (P = 0.013). Considering uncertain EEs as positive, sensitivity was 100% for SCR, 91% for LCR, and 82% for IRR (SCR versus IRR, P = 0.031) with 2D, 100%, 97%, and 87%, respectively, with 3D technique, without significant differences; specificity ranged from 71% to 90% with 2D and 61% to 83% with 3D, without significant differences.
CONCLUSION: The type of ROI influences the EE in dynamic breast MR. Using 3D technique with small ROI located on the area of maximal enhancement gives the best results in terms of certainty of the level of EE together with top levels of sensitivity.

Entities:  

Mesh:

Year:  2004        PMID: 15480038     DOI: 10.1097/01.rct.0000131582.75256.d5

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  5 in total

1.  MR imaging and proton spectroscopy of the breast: how to select the images useful to convey the diagnostic message.

Authors:  A Fausto; A Magaldi; B Babaei Paskeh; L Menicagli; E N Lupo; F Sardanelli
Journal:  Radiol Med       Date:  2007-10-21       Impact factor: 3.469

2.  A method for limiting pitfalls in the production of enhancement kinetic curves in 3T dynamic magnetic resonance mammography.

Authors:  Eleftherios Lavdas; Panayiotis Mavroidis; Violeta Roka; Nikolaos Arikidis; Dimitrios L Arvanitis; Ioannis V Fezoulidis; Katerina Vassiou
Journal:  J Thorac Dis       Date:  2012-08       Impact factor: 2.895

Review 3.  Breast MR imaging in women at high-risk of breast cancer. Is something changing in early breast cancer detection?

Authors:  Francesco Sardanelli; Franca Podo
Journal:  Eur Radiol       Date:  2006-09-29       Impact factor: 5.315

4.  Contrast-enhanced breast MR imaging of claustrophobic or oversized patients using an open low-field magnet.

Authors:  M Calabrese; D Brizzi; L Carbonaro; M Chiaramondia; M A Kirchin; F Sardanelli
Journal:  Radiol Med       Date:  2009-02-04       Impact factor: 3.469

5.  Breast MRI: guidelines from the European Society of Breast Imaging.

Authors:  R M Mann; C K Kuhl; K Kinkel; C Boetes
Journal:  Eur Radiol       Date:  2008-04-04       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.