Literature DB >> 15480001

Parallel imaging of the abdomen.

Daniel Jason Aaron Margolis1, Roland Bammer, Lawrence C Chow.   

Abstract

Parallel imaging holds great potential for improving the quality of diagnostic abdominal MRI. The increased imaging speed afforded by parallel imaging can be translated into the obvious benefits of reduced scan time with set resolution and coverage, improved spatial resolution with set imaging time and coverage, increased anatomic coverage for a set imaging time and resolution, or some combination of the above. Additionally, the reduction in scan time can also allow some sequences that normally require multiple breath-holds to be performed with only one, or simply make breath-hold imaging possible for more patients. The decreased echo-train length allows for truer T2-weighting, less magnetic susceptibility artifact, and less blurring with echo-train imaging. Dynamic contrast-enhanced sequences can be acquired with improved temporal or spatial resolution. All of these potential advantages come with the trade-off of decreased signal-to-noise ratio, but for many patients, the benefits far outweigh the drawbacks and can vastly improve the diagnostic quality of abdominal MRI.

Entities:  

Mesh:

Year:  2004        PMID: 15480001     DOI: 10.1097/01.rmr.0000136557.27727.79

Source DB:  PubMed          Journal:  Top Magn Reson Imaging        ISSN: 0899-3459


  5 in total

1.  Magnetic resonance imaging: Review of imaging techniques and overview of liver imaging.

Authors:  Santhi Maniam; Janio Szklaruk
Journal:  World J Radiol       Date:  2010-08-28

2.  Clinical evaluation of CAIPIRINHA: comparison against a GRAPPA standard.

Authors:  Katherine L Wright; Michael W Harrell; John A Jesberger; Luis Landeras; Dean A Nakamoto; Smitha Thomas; Dominik Nickel; Randall Kroeker; Mark A Griswold; Vikas Gulani
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

Review 3.  Assessment of abdominal adipose tissue and organ fat content by magnetic resonance imaging.

Authors:  H H Hu; K S Nayak; M I Goran
Journal:  Obes Rev       Date:  2011-02-23       Impact factor: 9.213

Review 4.  Parallel imaging artifacts in body magnetic resonance imaging.

Authors:  Patricia Noël; Roland Bammer; Caroline Reinhold; Masoom A Haider
Journal:  Can Assoc Radiol J       Date:  2009-04       Impact factor: 2.248

5.  Dynamic contrast-enhanced MRI of the prostate with high spatiotemporal resolution using compressed sensing, parallel imaging, and continuous golden-angle radial sampling: preliminary experience.

Authors:  Andrew B Rosenkrantz; Christian Geppert; Robert Grimm; Tobias K Block; Christian Glielmi; Li Feng; Ricardo Otazo; Justin M Ream; Melanie Moccaldi Romolo; Samir S Taneja; Daniel K Sodickson; Hersh Chandarana
Journal:  J Magn Reson Imaging       Date:  2014-05-16       Impact factor: 4.813

  5 in total