Literature DB >> 15479998

Reduced data acquisition methods in cardiac imaging.

Sebastian Kozerke1, Jeffrey Tsao.   

Abstract

In cardiac imaging, acquisition speed is of primary importance. While improved performance has mainly been achieved through improvements in gradient hardware in the past, further developments along this direction are limited due to physiological constraints such as the risk of peripheral nerve stimulation. With the introduction of parallel imaging, alternative means for increasing acquisition speed have become available. Using information from multiple receiver coils, images can be reconstructed from a sparsely sampled set of data. In practice, parallel imaging allows for 2- to 3-fold acceleration of the imaging process in typical cardiac applications. Further increases in acquisition speed are, however, difficult to achieve for current clinical field strengths and typical field of views. To address the limited gain in acquisition speed achievable with parallel imaging, a new set of methods has been proposed to take into account the similarity of image information at different time points during a dynamic series. Using these methods, 5- to 8-fold acceleration can be achieved in cardiac imaging. It is the purpose of this paper to review cardiac applications of reduced data acquisition methods with focus on parallel imaging and the recently developed k-t BLAST and k-t SENSE techniques.

Mesh:

Year:  2004        PMID: 15479998     DOI: 10.1097/01.rmr.0000132789.84706.9d

Source DB:  PubMed          Journal:  Top Magn Reson Imaging        ISSN: 0899-3459


  10 in total

Review 1.  Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.

Authors:  El-Sayed H Ibrahim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

2.  Stereolithographic reproduction of complex cardiac morphology based on high spatial resolution imaging.

Authors:  G F Greil; I Wolf; A Kuettner; M Fenchel; S Miller; P Martirosian; F Schick; M Oppitz; H-P Meinzer; L Sieverding
Journal:  Clin Res Cardiol       Date:  2007-01-22       Impact factor: 5.460

3.  2D phase contrast blood flow velocity measurements of the thoracic vasculature: comparison of the effect of gadofosveset trisodium and gadopentetate dimeglumine.

Authors:  Marcus R Makowski; Andrea J Wiethoff; Hans U Ebersberger; René M Botnar; Reza Razavi; Tobias Schaeffter; Gerald F Greil
Journal:  Int J Cardiovasc Imaging       Date:  2014-11-11       Impact factor: 2.357

Review 4.  The emerging role of cardiovascular magnetic resonance in the evaluation of Kawasaki disease.

Authors:  Sophie Mavrogeni; George Papadopoulos; Tarique Hussain; Amedeo Chiribiri; Rene Botnar; Gerald F Greil
Journal:  Int J Cardiovasc Imaging       Date:  2013-08-15       Impact factor: 2.357

5.  Assessment of local pulse wave velocity distribution in mice using k-t BLAST PC-CMR with semi-automatic area segmentation.

Authors:  Volker Herold; Stefan Herz; Patrick Winter; Fabian Tobias Gutjahr; Kristina Andelovic; Wolfgang Rudolf Bauer; Peter Michael Jakob
Journal:  J Cardiovasc Magn Reson       Date:  2017-10-16       Impact factor: 5.364

Review 6.  3D Whole Heart Imaging for Congenital Heart Disease.

Authors:  Gerald Greil; Animesh Aashoo Tandon; Miguel Silva Vieira; Tarique Hussain
Journal:  Front Pediatr       Date:  2017-02-27       Impact factor: 3.418

7.  Three dimensional three component whole heart cardiovascular magnetic resonance velocity mapping: comparison of flow measurements from 3D and 2D acquisitions.

Authors:  Lau Brix; Steffen Ringgaard; Allan Rasmusson; Thomas Sangild Sørensen; W Yong Kim
Journal:  J Cardiovasc Magn Reson       Date:  2009-02-20       Impact factor: 5.364

8.  Longitudinal strain from velocity encoded cardiovascular magnetic resonance: a validation study.

Authors:  Einar Heiberg; Ulrika Pahlm-Webb; Shruti Agarwal; Erik Bergvall; Helen Fransson; Katarina Steding-Ehrenborg; Marcus Carlsson; Håkan Arheden
Journal:  J Cardiovasc Magn Reson       Date:  2013-01-23       Impact factor: 5.364

9.  Magnetic resonance assessment of left ventricular volumes and mass using a single-breath-hold 3D k-t BLAST cine b-SSFP in comparison with multiple-breath-hold 2D cine b-SSFP.

Authors:  Erica Maffei; Giancarlo Messalli; Chiara Martini; Alexia Rossi; Niels van Pelt; Robert-Jan van Geuns; Annick C Weustink; Nico R Mollet; Koen Nieman; Annachiara Aldrovandi; Massimo Imbriaco; Jan Bogaert; Filippo Cademartiri
Journal:  Insights Imaging       Date:  2010-12-18

10.  Measurement of left ventricular dimensions with contrast-enhanced three-dimensional cine imaging facilitated by k-t SENSE.

Authors:  Neil Maredia; Sebastian Kozerke; Abdul Larghat; Nik Abidin; John P Greenwood; Peter Boesiger; Sven Plein
Journal:  J Cardiovasc Magn Reson       Date:  2008-05-28       Impact factor: 5.364

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.