Literature DB >> 15474834

Capsulorhexis ovaling and capsular bag stretch after rigid and foldable intraocular lens implantation: experimental study in pediatric human eyes.

Suresh K Pandey1, Liliana Werner, M Edward Wilson, Andrea M Izak, David J Apple.   

Abstract

PURPOSE: To compare the amount of capsulorhexis ovaling and capsular bag stretch produced by various intraocular lenses (IOLs) implanted in pediatric human eyes obtained post-mortem.
SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, Salt Lake City, Utah, USA.
METHODS: In this nonrandomized comparative study, 16 pediatric human eyes obtained postmortem were divided into 2 groups: Eight eyes were obtained from children younger than 2 years (Group A), and 8 eyes were obtained from children older than 2 years (Group B). All eyes were prepared according to the Miyake-Apple posterior video technique. Six types of rigid and foldable posterior chamber IOLs manufactured from poly(methyl methacrylate) (single-piece), silicone (plate and loop haptics), and hydrophobic acrylic (single-piece and 3-piece AcrySof, Alcon Laboratories) biomaterials were implanted. The capsulorhexis opening and capsular bag diameters were measured before IOL implantation and after in-the-bag IOL fixation with the haptics (or the main axis) at the 3 to 9 o'clock meridian. The percentage of ovaling of the capsulorhexis opening was calculated by noting the difference in the opening's horizontal diameter before and after IOL implantation. The percentage of capsular bag stretch was also calculated by noting the difference in the horizontal capsular bag diameter before and after IOL implantation.
RESULTS: All IOLs produced ovaling of the capsulorhexis opening and stretching of the capsular bag parallel to the IOL haptics. There were significant differences in capsulorhexis ovaling and capsular bag stretch (P<.001, analysis of variance) between the 6 IOL types in each group of eyes. The postimplantation difference was significant only between the single-piece hydrophobic acrylic IOL (AcrySof) and the other IOLs. The single-piece hydrophobic acrylic IOL was associated with significantly less capsulorhexis ovaling and capsular bag stretch in both groups (mean 12.06% +/- 0.59% [SD] and 7.6% +/- 1.47%, respectively).
CONCLUSIONS: Modern rigid and foldable IOLs designed for the adult population implanted in the capsular bag of infants and children produced variable degrees of capsulorhexis ovaling and capsular bag stretch. The Miyake-Apple posterior video technique confirmed the well-maintained configuration of the capsular bag (with minimal ovaling) after implantation of a single-piece hydrophobic acrylic IOL because of its flexible haptic design.

Entities:  

Mesh:

Year:  2004        PMID: 15474834     DOI: 10.1016/j.jcrs.2004.02.079

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  8 in total

1.  A Meta-analysis on the clinical efficacy and safety of optic capture in pediatric cataract surgery.

Authors:  Hong-Wei Zhou; Fang Zhou
Journal:  Int J Ophthalmol       Date:  2016-04-18       Impact factor: 1.779

Review 2.  [Pseudoexfoliation syndrome and cataract surgery. Avoidance and treatment of complications].

Authors:  R Menapace
Journal:  Ophthalmologe       Date:  2012-10       Impact factor: 1.059

3.  Refractive accuracy after intraocular lens implantation in pediatric cataract.

Authors:  Tan Long; Yu-Sen Huang; Li-Xin Xie
Journal:  Int J Ophthalmol       Date:  2012-08-18       Impact factor: 1.779

4.  Visual results and complications of primary intraocular lens implantation in infants aged 6 to 12 months.

Authors:  Yi Lu; Ying-Hong Ji; Yi Luo; Yong-Xiang Jiang; Man Wang; Xu Chen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-02-17       Impact factor: 3.117

5.  Postoperative posterior capsular striae and the posterior capsular opacification in patients implanted with two types of intraocular lens material.

Authors:  Rajesh Subhash Joshi
Journal:  Indian J Ophthalmol       Date:  2017-06       Impact factor: 1.848

6.  Comparison of Anterior Capsule Stability Following Implantation of Three Single Piece Acrylic Intraocular Lenses with Different Haptic Design.

Authors:  Soonwon Yang; Sung A Lim; Kyung-Sun Na; Choun-Ki Joo
Journal:  Korean J Ophthalmol       Date:  2017-02-02

7.  Management of cataracts and ectopia lentis in children: Practice patterns of pediatric ophthalmologists in India.

Authors:  Vasudha Kemmanu; Pragnya Rathod; Harsha L Rao; Sumitha Muthu; Chaitra Jayadev
Journal:  Indian J Ophthalmol       Date:  2017-09       Impact factor: 1.848

8.  Femtosecond laser-assisted refractive capsulorhexis - Precise capsulotomy with accurate toric intraocular lens alignment.

Authors:  Manpreet Kaur; Jeewan Singh Titiyal; Farin Shaikh; Deeksha Rani
Journal:  Indian J Ophthalmol       Date:  2020-11       Impact factor: 1.848

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.