Literature DB >> 15474829

PermaVision intracorneal lens for the correction of hyperopia.

Paolo Michieletto1, Edoardo Ligabue, Alessandra Balestrazzi, Angelo Balestrazzi, Salvatore Giglio.   

Abstract

PURPOSE: To evaluate the safety, predictability, and efficacy of sutureless synthetic keratophakia (SSK) with PermaVision intracorneal lens (Anamed) implantation.
SETTING: Ophthalmic Hospital, Rome, Italy.
METHODS: This retrospective study analyzed the refractive outcomes in 10 eyes of 6 patients who had SSK with PermaVision lens implantation for spherical hyperopia (cylinder less than 1.0 diopter [D]). Preoperatively, the mean spherical equivalent (SE) refraction was +4.33 D +/- 1.52 (SD) (range +3.00 to +6.37 D). All procedures were performed using the Hansatome microkeratome (Bausch & Lomb) with a superior hinge except in 1 eye in which the flap was cut using the Amadeus microkeratome (Allergan) with a nasal hinge.
RESULTS: Six months after PermaVision lens insertion, the mean SE refraction was +0.03 +/- 0.36 D (range -0.50 to +0.38 D), the mean uncorrected visual acuity was 0.85 +/- 0.13 (range 0.63 to 1.00), and the mean best corrected visual acuity was 0.99 +/- 0.19 (range 0.63 to 1.25). No eye lost lines of visual acuity. In 1 eye, the lens was acutely decentered and had to be explanted.
CONCLUSIONS: Sutureless synthetic keratophakia with the PermaVision intracorneal lens is a new technique for the correction of hyperopia. It is easy to perform as well as reversible, and the learning curve of the experienced laser in situ keratomileusis surgeon is short. The technique was safe and effective for spherical hyperopia, but longer follow-up and additional cases are needed to draw conclusions about the efficacy of the technique.

Entities:  

Mesh:

Year:  2004        PMID: 15474829     DOI: 10.1016/j.jcrs.2004.02.093

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  2 in total

1.  Unilateral Keratectasia Treated with Femtosecond Fashioned Intrastromal Corneal Inlay.

Authors:  Khosrow Jadidi; Hossein Hasanpour
Journal:  J Ophthalmic Vis Res       Date:  2017 Jul-Sep

2.  Confocal and Histological Features After Poly(Ethylene Glycol) Diacrylate Corneal Inlay Implantation.

Authors:  Aritz Bidaguren; Javier Mendicute; Iratxe Madarieta; Nerea Garagorri
Journal:  Transl Vis Sci Technol       Date:  2019-12-18       Impact factor: 3.283

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.