Literature DB >> 15474744

Muscle ultrasound in children: normal values and application to neuromuscular disorders.

Natalia Maria Maurits1, Ernesto Alexander Christiaan Beenakker, David Eric Christiaan van Schaik, Johanna Maria Fock, Johannes Harmen van der Hoeven.   

Abstract

In this study, 105 healthy children (45 to 156 months old, 57 girls) were examined using ultrasound (US) imaging to obtain reference values of muscle dimensional and aspect parameters. We measured biceps and quadriceps sizes and subcutaneous tissue thickness. To quantify muscle aspect, we calculated muscle density, inhomogeneity and white-area index by digital image analysis. Age-, weight- and gender-dependencies were discussed. We demonstrated earlier that the complete set of parameters allows for differentiation between myopathies and neuropathies in adults, with high sensitivity. In this study, we investigated if these parameters have additional value in the diagnostic evaluation of 36 children with proven neuromuscular disease (20 Duchenne muscular dystrophy, 16 neuropathies). We found that density analysis provides a sensitive method for distinguishing between healthy children and children with neuromuscular disorders. We have also found that more detailed aspect analysis is necessary to further distinguish between these types of neuromuscular disorders in children. In conclusion, this set of normal muscle parameters can be used to help diagnose neuromuscular disorders in children. It will also facilitate follow-up in disease progression and therapy.

Entities:  

Mesh:

Year:  2004        PMID: 15474744     DOI: 10.1016/j.ultrasmedbio.2004.05.013

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  15 in total

1.  Sonoanatomy relevant for ultrasound-guided central neuraxial blocks via the paramedian approach in the lumbar region.

Authors:  M K Karmakar; X Li; W H Kwok; A M-H Ho; W D Ngan Kee
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

2.  Quantitative evaluation of the echo intensity of the median nerve and flexor muscles of the forearm in the young and the elderly.

Authors:  X Li; M K Karmakar; A Lee; W H Kwok; L A H Critchley; T Gin
Journal:  Br J Radiol       Date:  2011-10-18       Impact factor: 3.039

3.  Lean and fat mass loss in obese patients before and after Roux-en-Y gastric bypass: a new application for ultrasound technique.

Authors:  A Z Pereira; J S Marchini; G Carneiro; C H Arasaki; M T Zanella
Journal:  Obes Surg       Date:  2012-04       Impact factor: 4.129

Review 4.  Imaging and skeletal muscle disease.

Authors:  Nancy J Olsen; Jing Qi; Jane H Park
Journal:  Curr Rheumatol Rep       Date:  2005-04       Impact factor: 4.592

5.  Quantification of Muscle Tissue Properties by Modeling the Statistics of Ultrasound Image Intensities Using a Mixture of Gamma Distributions in Children With and Without Cerebral Palsy.

Authors:  Siddhartha Sikdar; Guoqing Diao; Diego Turo; Christopher J Stanley; Abhinav Sharma; Amy Chambliss; Loretta Laughrey; April Aralar; Diane L Damiano
Journal:  J Ultrasound Med       Date:  2018-02-20       Impact factor: 2.153

6.  Skeletal muscle quality assessed from echo intensity is associated with muscle strength of middle-aged and elderly persons.

Authors:  Yoshihiro Fukumoto; Tome Ikezoe; Yosuke Yamada; Rui Tsukagoshi; Masatoshi Nakamura; Natsuko Mori; Misaka Kimura; Noriaki Ichihashi
Journal:  Eur J Appl Physiol       Date:  2011-08-17       Impact factor: 3.078

7.  Assessing spinal muscular atrophy with quantitative ultrasound.

Authors:  Jim S Wu; Basil T Darras; Seward B Rutkove
Journal:  Neurology       Date:  2010-08-10       Impact factor: 9.910

8.  Reliability and Validity of an Ultrasound-Based Protocol for Measurement of Quadriceps Muscle Thickness in Children.

Authors:  Emil Rydell Högelin; Kajsa Thulin; Ferdinand von Walden; Lotta Fornander; Piotr Michno; Björn Alkner
Journal:  Front Physiol       Date:  2022-06-27       Impact factor: 4.755

9.  Sensitive ultrasonic detection of dystrophic skeletal muscle in patients with duchenne muscular dystrophy using an entropy-based signal receiver.

Authors:  Michael S Hughes; Jon N Marsh; Kirk D Wallace; Tamara A Donahue; Anne M Connolly; Gregory M Lanza; Samuel A Wickline
Journal:  Ultrasound Med Biol       Date:  2007-04-30       Impact factor: 2.998

10.  In spina bifida aperta, muscle ultrasound can quantify the "second hit of damage".

Authors:  R J Verbeek; J H van der Hoeven; N M Maurits; O F Brouwer; E W Hoving; D A Sival
Journal:  Childs Nerv Syst       Date:  2012-11-09       Impact factor: 1.475

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.