Abstract

OBJECTIVE: To compare energy cost and stride characteristics during walking with 3 different types of prostheses in a person with bilateral knee disarticulations.
DESIGN: Single-case study. Setting Pathokinesiology laboratory. PARTICIPANT: A subject with bilateral knee disarticulations and bilateral transradial amputations secondary to meningococcemia with purpura fulminans.
INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Energy cost, stride characteristics, and motion analysis.
RESULTS: When wearing the C-Leg prostheses, the subject walked the farthest and fastest, with an overall lower rate of oxygen consumption and oxygen cost compared with walking with either of the other prostheses. Gait analysis while the patient was wearing the C-Leg prostheses revealed premature hip extension, absence of knee flexion during loading response, and a rate of swing in the referent range.
CONCLUSIONS: Walking in a C-leg was the most efficient method of ambulation for our subject.

Entities:  

Mesh:

Year:  2004        PMID: 15468036     DOI: 10.1016/j.apmr.2004.02.028

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  7 in total

1.  Powered lower limb orthoses for gait rehabilitation.

Authors:  Daniel P Ferris; Gregory S Sawicki; Antoinette Domingo
Journal:  Top Spinal Cord Inj Rehabil       Date:  2005

2.  Gait asymmetry of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees.

Authors:  Kenton R Kaufman; Serena Frittoli; Carlo A Frigo
Journal:  Clin Biomech (Bristol, Avon)       Date:  2012-01-04       Impact factor: 2.063

3.  Energy expenditure and activity of transfemoral amputees using mechanical and microprocessor-controlled prosthetic knees.

Authors:  Kenton R Kaufman; James A Levine; Robert H Brey; Shelly K McCrady; Denny J Padgett; Michael J Joyner
Journal:  Arch Phys Med Rehabil       Date:  2008-07       Impact factor: 3.966

Review 4.  Measures and procedures utilized to determine the added value of microprocessor-controlled prosthetic knee joints: a systematic review.

Authors:  Patrick J R Theeven; Bea Hemmen; Peter R G Brink; Rob J E M Smeets; Henk A M Seelen
Journal:  BMC Musculoskelet Disord       Date:  2013-11-27       Impact factor: 2.362

5.  Adaptation and prosthesis effects on stride-to-stride fluctuations in amputee gait.

Authors:  Shane R Wurdeman; Sara A Myers; Adam L Jacobsen; Nicholas Stergiou
Journal:  PLoS One       Date:  2014-06-23       Impact factor: 3.240

6.  Towards active lower limb prosthetic systems: design issues and solutions.

Authors:  Oliver Christ; Philipp Beckerle
Journal:  Biomed Eng Online       Date:  2016-12-19       Impact factor: 2.819

7.  Powered knee and ankle prostheses enable natural ambulation on level ground and stairs for individuals with bilateral above-knee amputation: a case study.

Authors:  Sarah Hood; Suzi Creveling; Lukas Gabert; Minh Tran; Tommaso Lenzi
Journal:  Sci Rep       Date:  2022-09-14       Impact factor: 4.996

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.