Literature DB >> 15465545

Ophtec iris reconstruction lens United States clinical trial phase I.

Marianne O Price1, Francis W Price, David F Chang, Kathy Kelley, Michael D Olson, Kevin M Miller.   

Abstract

PURPOSE: To determine the safety and efficacy of the Ophtec model 311 iris reconstruction lens for treatment of visual disturbances, such as glare or photophobia, related to partial or total absence of the human iris.
DESIGN: Phase I multicenter, nonrandomized, investigational device study. PARTICIPANTS: Ten iris reconstruction lenses were placed in 10 subjects at 6 sites.
METHODS: Iris reconstruction lenses were placed in 9 patients who had lost all or part of their iris from trauma and in 1 patient who lacked iris pigmentation due to congenital albinism. Patients were examined preoperatively, intraoperatively, and postoperatively at day 1; week 1; and months 1, 3, 6, and 12. MAIN OUTCOME MEASURES: Efficacy measures were uncorrected visual acuity (UCVA), glare, starbursts, and photophobia. Safety measures were best-corrected visual acuity (VA), surgical complications, and adverse events.
RESULTS: Uncorrected VA improved in all eyes after implantation of the iris reconstruction lens. Best-corrected VA did not change significantly (P = 0.24). Postoperative photophobia was reduced in all 9 eyes that experienced moderate to severe preoperative photophobia. Likewise, postoperative glare was reduced in all 6 eyes with moderate to severe preoperative glare. There were no surgical complications. Adverse events included 2 cases of iritis and 1 case of macular edema.
CONCLUSIONS: Preliminary results suggest that the Ophtec model 311 iris reconstruction lens can improve UCVA and reduce glare and photophobia in patients with partial or total absence of the iris or iris pigmentation.

Entities:  

Mesh:

Year:  2004        PMID: 15465545     DOI: 10.1016/j.ophtha.2004.04.023

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  6 in total

1.  Simultaneous correction of post-traumatic aphakia and aniridia with the use of artificial iris and IOL implantation.

Authors:  Cesare Forlini; Matteo Forlini; Robert Rejdak; Agata Prokopiuk; Oxana Levkina; Adriana Bratu; Paolo Rossini; Perfecto R Cagampang; Gian Maria Cavallini
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-01-17       Impact factor: 3.117

2.  Chronic post-operative iris prosthesis endophthalmitis in a patient with traumatic aniridia: a case report.

Authors:  Kevin C Firl; Sandra R Montezuma
Journal:  BMC Ophthalmol       Date:  2016-11-09       Impact factor: 2.209

3.  Sutured Custom Foldable Silicone Artificial Iris Implantation Combined With Intraocular Lens Implantation and Penetrating Keratoplasty: Safety and Efficacy Outcomes.

Authors:  Clemence Bonnet; Parsia Vazirnia; Sophie X Deng; Anthony J Aldave; Kevin M Miller
Journal:  Cornea       Date:  2021-10-01       Impact factor: 2.651

4.  Novel surgical technique of sutureless artificial iris and intraocular lens scleral fixation using Yamane technique.

Authors:  Daniel Rudolf Muth; Siegfried Georg Priglinger; Mehdi Shajari; Thomas Christian Kreutzer; Wolfgang Johann Mayer
Journal:  Am J Ophthalmol Case Rep       Date:  2022-03-25

5.  Lessons Learned from Implantation of Morcher 50D and 96S Artificial Iris Diaphragms.

Authors:  Shawn R Lin; Kevin M Miller
Journal:  Case Rep Ophthalmol       Date:  2017-11-23

6.  Traumatic Aniridia and Aphakia Management with Iris Reconstruction Lens Using Gore-Tex Sutures, an Ab-Externo Approach.

Authors:  Efstratios Parikakis; Georgios Batsos; Loukas Kontomichos; Vasileios Peponis; Eleni Christodoulou; Dimitrios Karagiannis
Journal:  Am J Case Rep       Date:  2020-09-22
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.