Literature DB >> 15464530

Simple modification of "T. David-V" valve-sparing aortic root replacement to create graft pseudosinuses.

Philippe Demers1, D Craig Miller.   

Abstract

The absence of sinuses of Valsalva is postulated to perturb coronary flow patterns and to create abnormal leaflet stresses, which theoretically may limit the long-term durability of valve-sparing aortic root replacement with the original Tirone David-I reimplantation technique with a cylindrical tube graft. David developed the "T. David-V" procedure in 2001; it creates large billowing Dacron pseudosinuses while retaining the reimplantation concept. To illustrate a simple modification of the T. David-V technique, we describe a patient with Marfan's syndrome who underwent valve-sparing aortic root replacement with 1 large and 1 small graft to create pseudosinuses in the Dacron graft, to facilitate suturing the valve inside the graft, and to make the distal graft-to-aorta anastomosis a better size match.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15464530     DOI: 10.1016/j.athoracsur.2003.08.032

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  9 in total

1.  Graft sizing for aortic valve sparing surgery.

Authors:  Munir Boodhwani; Gebrine El Khoury; Laurent de Kerchove
Journal:  Ann Cardiothorac Surg       Date:  2013-01

Review 2.  Postoperative imaging of the aorta.

Authors:  Weier Li; Sasiprapa Rongthong; Anand M Prabhakar; Sandeep Hedgire
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

Review 3.  Surgery for thoracic aortic disease in Japan: evolving strategies toward the growing enemies.

Authors:  Yutaka Okita
Journal:  Gen Thorac Cardiovasc Surg       Date:  2014-10-07

Review 4.  Pre- and Postoperative Imaging of the Aortic Root.

Authors:  Kate Hanneman; Frandics P Chan; R Scott Mitchell; D Craig Miller; Dominik Fleischmann
Journal:  Radiographics       Date:  2015-11-27       Impact factor: 5.333

5.  Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement.

Authors:  Reza Tavakoli; Guillaume Lebreton; Max Gassmann; Peiman Jamshidi; Pascal Leprince
Journal:  J Vis Exp       Date:  2017-12-11       Impact factor: 1.355

6.  Initial Surgical Experience with Aortic Valve Repair: Clinical and Echocardiographic Results.

Authors:  Francisco Diniz Affonso da Costa; Daniele de Fátima Fornazari Colatusso; Ana Claudia Brenner Affonso da Costa; Eduardo Mendel Balbi Filho; Vinicius Nesi Cavicchioli; Sergio Augusto Veiga Lopes; Andrea Dumsch de Aragon Ferreira; Claudinei Collatusso
Journal:  Braz J Cardiovasc Surg       Date:  2016-04

7.  Comparison of Hemodynamics After Aortic Root Replacement Using Valve-Sparing or Bioprosthetic Valved Conduit.

Authors:  Jeremy D Collins; Edouard Semaan; Alex Barker; Patrick M McCarthy; James C Carr; Michael Markl; S Chris Malaisrie
Journal:  Ann Thorac Surg       Date:  2015-07-23       Impact factor: 4.330

8.  Early and Midterm Outcomes of the VSSR procedure with De Paulis valsalva graft: A Chinese single-Center Experience in 38 patients.

Authors:  Lili Xu; Feng Gao; Ping Li; Yi Xu; Shuo Liu; Bing You; Li-Zhong Sun
Journal:  J Cardiothorac Surg       Date:  2015-11-19       Impact factor: 1.637

Review 9.  Post-operative computed tomography imaging evaluation of ascending aorta surgery.

Authors:  Patrizia Toia; Luciano Pennisi; Rossana Taravella; Emanuele Grassedonio; Cesare Gagliardo; Massimo Galia; Massimo Midiri; Ludovico La Grutta
Journal:  Pol J Radiol       Date:  2021-04-28