Literature DB >> 15457427

Winner of the 2003 James A. Rand Young Investigator's Award. Early failure of cementless mobile-bearing total knee arthroplasty.

Robert L Barrack1, Shawn J Nakamura, Shelby G Hopkins, Seth Rosenzweig.   

Abstract

A consecutive series of 82 cementless mobile-bearing total knee arthroplasties performed was studied to determine the reliability of cementless tibial component fixation. The indications for surgery in all cases were osteoarthritis with only mild or moderate deformity. Evaluation consisted of a Knee Society clinical score (KSCS) and radiographic evaluation preoperatively and at annual follow-up. Minimum 2-year follow-up was obtained in 73 of 82 knees (89%). Results were compared to those of a subsequent consecutive series of 76 knees (66 with 2-year follow-up) performed with a mobile-bearing TKA with cemented components with the same indications, implant, technique, and length of follow-up. Six of 73 cementless mobile-bearing TKAs (8%) underwent tibial component revision for symptomatic subsidence and failure of ingrowth compared to 0/66 revisions in the cemented group (P<.05). Patients with cementless mobile-bearing TKA also had a significantly lower KSCS (161 versus 184, P<.05), significantly higher incidence of pain rated more than mild (23% versus 7%, P<.01) and a trend toward less arc of motion (106 degrees versus 115 degrees, P<.2). The results do not support the hypothesis that mobile-bearing TKA imparts the advantage of reliable tibial bone ingrowth.

Entities:  

Mesh:

Year:  2004        PMID: 15457427     DOI: 10.1016/j.arth.2004.06.007

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  No early tibial tray loosening after surface cementing technique in mobile-bearing TKA.

Authors:  Roberto Rossi; Matteo Bruzzone; Davide Edoardo Bonasia; Andrea Ferro; Filippo Castoldi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-06-10       Impact factor: 4.342

2.  The Mark Coventry Award: Trabecular metal tibial components were durable and reliable in primary total knee arthroplasty: a randomized clinical trial.

Authors:  Luis Pulido; Matthew P Abdel; David G Lewallen; Michael J Stuart; Joaquin Sanchez-Sotelo; Arlen D Hanssen; Mark W Pagnano
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

3.  Five-year experience of cementless Oxford unicompartmental knee replacement.

Authors:  H G Pandit; S Campi; T W Hamilton; O D Dada; S Pollalis; C Jenkins; C A F Dodd; D W Murray
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-26       Impact factor: 4.342

4.  No clinical benefit of titanium nitride coating in cementless mobile-bearing total knee arthroplasty.

Authors:  Ruud P van Hove; Richard M Brohet; Barend J van Royen; Peter A Nolte
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-10-05       Impact factor: 4.342

5.  Navigated cementless total knee arthroplasty - medium-term clinical and radiological results.

Authors:  Jan P Schüttrumpf; Peter Balcarek; Stephan Sehmisch; Stephan Frosch; Martin M Wachowski; Klaus M Stürmer; Hans-Joachim Walde; Tim A Walde
Journal:  Open Orthop J       Date:  2012-04-16

6.  Study on implant stability in cementless total knee arthroplasty.

Authors:  Luís Eduardo Passarelli Tírico; Thiago Pasqualin; José Otávio Pécora; Riccardo Gomes Gobbi; José Ricardo Pécora; Marco Kawamura Demange
Journal:  Acta Ortop Bras       Date:  2012       Impact factor: 0.513

7.  The effect of fixation type on the survivorship of contemporary total knee arthroplasty in patients younger than 65 years of age: a register-based study of 115,177 knees in the Nordic Arthroplasty Register Association (NARA) 2000-2016.

Authors:  Mika J Niemeläinen; Keijo T Mäkelä; Otto Robertsson; Annette W-Dahl; Ove Furnes; Anne M Fenstad; Alma B Pedersen; Henrik M Schrøder; Aleksi Reito; Antti Eskelinen
Journal:  Acta Orthop       Date:  2020-01-13       Impact factor: 3.717

8.  Sagittal component alignment is less reliable than coronal component alignment in a Chinese population undergoing navigated TKA.

Authors:  Xiaoyong Chen; Huayi Wang; Yuanzhen Cai; Qingsheng Zhu; Jinyu Zhu
Journal:  J Orthop Surg Res       Date:  2014-07-06       Impact factor: 2.359

9.  Early Clinical Outcomes of a New Posteriorly Stabilized Total Knee Arthroplasty Prosthesis: Comparisons with Two Established Prostheses.

Authors:  Nimesh P Jain; Sung Yup Lee; Vivek M Morey; Suri Chong; Yeon Gwi Kang; Tae Kyun Kim
Journal:  Knee Surg Relat Res       Date:  2017-09-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.