Literature DB >> 15457420

Early morbidity of modular exchange for polyethylene wear and osteolysis.

William L Griffin1, Thomas K Fehring, J Bohannon Mason, Thomas H McCoy, Susan Odum, Christi Sychterz Terefenko.   

Abstract

This study assessed the early morbidity associated with modular component exchange surgery for the treatment of accelerated polyethylene wear and osteolysis in 55 patients. Review of the surgical records revealed no significant intraoperative complications, little intraoperative blood loss (mean 333 mL), no allogenic blood transfusions, and no recorded postoperative deep vein thromboses. Eighteen percent of patients, however, experienced postoperative dislocation. Five patients dislocated multiple times, 3 of which required rerevision surgery. Two patients required rerevision for femoral implant fractures related to osteolysis and 1 additional patient required rerevision due to catastrophic failure of the acetabular component 5 years postoperatively. With an average follow-up of 30 months, 6 of the 55 patients treated with modular exchange required rerevision. The results of this study suggest that instability is the most prevalent early complication associated with modular component exchange. As such, we believe that more stable constructs should be emphasized, possibly at the expense of polyethylene thickness.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15457420     DOI: 10.1016/j.arth.2004.06.014

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

Review 1.  The surgical options and clinical evidence for treatment of wear or corrosion occurring with THA or TKA.

Authors:  Charles A Engh; Henry Ho; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

2.  A three-dimensional method for evaluating changes in acetabular osteolytic lesions in response to treatment.

Authors:  Hiroshi Egawa; Henry Ho; Cathy Huynh; Robert H Hopper; C Anderson Engh; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2009-08-22       Impact factor: 4.176

3.  Corrosion at the head-neck taper as a cause for adverse local tissue reactions after total hip arthroplasty.

Authors:  H John Cooper; Craig J Della Valle; Richard A Berger; Matthew Tetreault; Wayne G Paprosky; Scott M Sporer; Joshua J Jacobs
Journal:  J Bone Joint Surg Am       Date:  2012-09-19       Impact factor: 5.284

4.  Isolated Acetabular Liner Exchange for Polyethylene Wear and Osteolysis with Well-Fixed Metal Shell.

Authors:  Kyung Wook Kim; Jeong Joon Yoo; Min Nyun Kim; Hee Joong Kim
Journal:  Clin Orthop Surg       Date:  2019-08-12

Review 5.  The Diagnosis and Treatment of Acetabular Bone Loss in Revision Hip Arthroplasty: An International Consensus Symposium.

Authors:  Peter K Sculco; Timothy Wright; Michael-Alexander Malahias; Alexander Gu; Mathias Bostrom; Fares Haddad; Seth Jerabek; Michael Bolognesi; Thomas Fehring; Alejandro Gonzalez DellaValle; William Jiranek; William Walter; Wayne Paprosky; Donald Garbuz; Thomas Sculco
Journal:  HSS J       Date:  2021-09-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.