Literature DB >> 15455367

Thermal risks from LED- and high-intensity QTH-curing units during polymerization of dental resins.

Serge Bouillaguet1, Guillaume Caillot, Jacques Forchelet, Maria Cattani-Lorente, John C Wataha, Ivo Krejci.   

Abstract

The aim of this study was to test the ability of an infrared (IR) camera to assess temperature changes and distributions in teeth below restorations when quartz-tungsten-halogen (QTH) and light-emitting diode (LED) curing lights were used to photopolymerize the restorative material. Our hypothesis was that the higher power density and broader spectral distribution of the QTH source would cause greater increases in tooth temperature than the LED source, and that these differences would be best demonstrated with the IR camera. Cavities were prepared on human third molars and restored with a resin composite restorative material. The material was light-cured using three light-curing sources using several exposure times. The external (outside the tooth) and internal (inside the pulp chamber) temperature changes during polymerization of the composite material were recorded over 360 s with thermocouples and an IR camera. Using thermocouples the maximum increase in external temperature (+17.7 degrees C) was reported for the Swiss Master light after 20 s of curing time while the minimum temperature rise (+7.8 degrees C) was reported for the Freelight 2. Whereas a 2.6 degrees C increase in internal temperature was observed after curing 20 s with the Freelight 2, 7.1 degrees C was reported after 60 s of light exposure to Astralis 10. Infrared images showed similar trends in external-internal rises in temperature as the thermocouples, although temperatures measured by the IR were generally higher. These results indicate that the higher power density QTH sources caused greater increases in tooth temperatures than the LED source and that thermocouples may underestimate the heat applied to the tooth.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15455367     DOI: 10.1002/jbm.b.30143

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  13 in total

1.  The applicability of DPSS laser for light curing of composite resins.

Authors:  Yong Hoon Kwon; Chang-Min Jang; Dong-Hee Shin; Hyo-Joung Seol; Hyung-Il Kim
Journal:  Lasers Med Sci       Date:  2007-09-28       Impact factor: 3.161

2.  Effect of diode-pumped solid state laser on polymerization shrinkage and color change in composite resins.

Authors:  Yun-Hoa Jung; Bong-Hae Cho; Kyung-Soo Nah; Hyung-Il Kim; Yong Hoon Kwon
Journal:  Lasers Med Sci       Date:  2009-02-10       Impact factor: 3.161

3.  Characterization of heat emission of light-curing units.

Authors:  Mohammed A Wahbi; F A Aalam; F I Fatiny; S A Radwan; I Y Eshan; K H Al-Samadani
Journal:  Saudi Dent J       Date:  2012-03-09

4.  The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites.

Authors:  Matej Par; Igor Repusic; Hrvoje Skenderovic; Ognjen Milat; Jelena Spajic; Zrinka Tarle
Journal:  Clin Oral Investig       Date:  2019-01-28       Impact factor: 3.573

Review 5.  [Effect of preheating on the properties of resin composite].

Authors:  Jing Xue; Bi-Na Yang
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2019-12-01

6.  Comparison of Depth of Cure, Hardness and Heat Generation of LED and High Intensity QTH Light Sources.

Authors:  Sayed Mostafa Mousavinasab; Ian Meyers
Journal:  Eur J Dent       Date:  2011-07

7.  Temperature changes under demineralized dentin during polymerization of three resin-based restorative materials using QTH and LED units.

Authors:  Sayed-Mostafa Mousavinasab; Maryam Khoroushi; Mohammadreza Moharreri; Mohammad Atai
Journal:  Restor Dent Endod       Date:  2014-05-13

8.  Thermal Scanning of Dental Pulp Chamber by Thermocouple System and Infrared Camera during Photo Curing of Resin Composites.

Authors:  Faeze Hamze; Seyed Abdolreza Ganjalikhan Nasab; Ali Eskandarizadeh; Arash Shahravan; Fatemeh Akhavan Fard; Neda Sinaee
Journal:  Iran Endod J       Date:  2018

9.  Effect of light curing unit on resin-modified glass-ionomer cements: a microhardness assessment.

Authors:  Daniela Francisca Gigo Cefaly; Liliam Lucia Carrara Paes de Mello; Linda Wang; José Roberto Pereira Lauris; Paulo Henrique Perlatti D'Alpino
Journal:  J Appl Oral Sci       Date:  2009 May-Jun       Impact factor: 2.698

10.  Light-curing units used in dentistry: factors associated with heat development-potential risk for patients.

Authors:  Mathieu Mouhat; James Mercer; Lina Stangvaltaite; Ulf Örtengren
Journal:  Clin Oral Investig       Date:  2016-10-01       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.