Literature DB >> 1544960

Early migration of prostheses related to long-term survivorship. Comparison of tibial components in knee replacement.

R Grewal1, M G Rimmer, M A Freeman.   

Abstract

We determined the cumulative survival rates, in arthroplasty of the knee, of three designs of tibial component, using a change of position on standard radiographs or revision for aseptic loosening as criteria of failure. The average migration of each of the three designs in the first postoperative year is known from roentgen stereophotogrammetric analysis reported by other authors. The ranking order of the components as judged by cumulative survival is the same as that determined by early migration. This finding supports the view that the measurement of early migration can predict late aseptic loosening and therefore that such measurements are clinically of value.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1544960

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  20 in total

Review 1.  How to read a postoperative knee replacement radiograph.

Authors:  Nawfal Al-Hadithy; Madhavan C Papanna; Sana Farooq; Yegappan Kalairajah
Journal:  Skeletal Radiol       Date:  2011-10-16       Impact factor: 2.199

Review 2.  Tibial component designs in primary total knee arthroplasty: should we reconsider all-polyethylene component?

Authors:  Tao Cheng; Xiaoyun Pan; Tao Liu; Xianlong Zhang
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-05       Impact factor: 4.342

3.  CORR Insights ®: The Oxford unicompartmental knee fails at a high rate in a high-volume knee practice.

Authors:  John M Clark
Journal:  Clin Orthop Relat Res       Date:  2013-08-24       Impact factor: 4.176

4.  Roentgen stereophotogrammetric analysis: an effective tool to predict implant survival after an all-poly unicompartmental knee arthroplasty-a 10 year follow-up study.

Authors:  Danilo Bruni; Laura Bragonzoni; Michele Gagliardi; Marco Bontempi; Ibrahim Akkawi; Giovanni Francesco Raspugli; Francesco Iacono; Silvio Patella; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-11       Impact factor: 4.342

5.  Current techniques in total knee replacement: results of a national survey.

Authors:  A M Phillips; N J Goddard; J E Tomlinson
Journal:  Ann R Coll Surg Engl       Date:  1996-11       Impact factor: 1.891

6.  No difference in terms of radiostereometric analysis between fixed- and mobile-bearing total knee arthroplasty: a randomized, single-blind, controlled trial.

Authors:  M G M Schotanus; P Pilot; B L Kaptein; W F Draijer; P B J Tilman; R Vos; N P Kort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-27       Impact factor: 4.342

Review 7.  Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.

Authors:  Bart G Pijls; Edward R Valstar; Klaas-Auke Nouta; Josepha Wm Plevier; Marta Fiocco; Saskia Middeldorp; Rob Ghh Nelissen
Journal:  Acta Orthop       Date:  2012-11-09       Impact factor: 3.717

8.  Trabecular metal tibia still stable at 5 years: an RSA study of 36 patients aged less than 60 years.

Authors:  Anders Henricson; Dan Rösmark; Kjell G Nilsson
Journal:  Acta Orthop       Date:  2013-05-13       Impact factor: 3.717

9.  Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh: a randomized clinical RSA study on cementless tibial components.

Authors:  Maiken Stilling; Frank Madsen; Anders Odgaard; Lone Rømer; Niels Trolle Andersen; Ole Rahbek; Kjeld Søballe
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

10.  Continued stabilization of trabecular metal tibial monoblock total knee arthroplasty components at 5 years-measured with radiostereometric analysis.

Authors:  David A J Wilson; Glen Richardson; Allan W Hennigar; Michael J Dunbar
Journal:  Acta Orthop       Date:  2011-12-29       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.