Limitation of the achievable signal-to-noise ratio in optical coherence tomography due to mismatch of the balanced receiver.

Carla Carmelo Rosa1, Adrian Gh Podoleanu.   

Abstract

Owing to the limited spectral response of the fiber directional coupler used in a balanced optical coherence tomography configuration, the spectra are different in the two outputs. This affects unfavorably operation of the balanced photodetector unit. Excess photon noise makes a larger contribution than a directional coupler with a flat spectral response. A theoretical model is developed that shows that an optimum set of parameters may be defined to maximize the achievable signal-to-noise ratio. The model leads to a redefinition of the effective noise bandwidth, which takes into account the nonflat response of the directional coupler used. The model also predicts a limitation on the signal-to-noise ratio even when the stray reflectances in the interferometer are brought to zero.

Year:  2004        PMID: 15449466     DOI: 10.1364/ao.43.004802

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  6 in total

1.  Ultra-widefield retinal MHz-OCT imaging with up to 100 degrees viewing angle.

Authors:  Jan Philip Kolb; Thomas Klein; Corinna L Kufner; Wolfgang Wieser; Aljoscha S Neubauer; Robert Huber
Journal:  Biomed Opt Express       Date:  2015-04-02       Impact factor: 3.732

Review 2.  Optical coherence tomography: fundamental principles, instrumental designs and biomedical applications.

Authors:  Dan P Popescu; Lin-P'ing Choo-Smith; Costel Flueraru; Youxin Mao; Shoude Chang; John Disano; Sherif Sherif; Michael G Sowa
Journal:  Biophys Rev       Date:  2011-08-06

3.  High-resolution retinal swept source optical coherence tomography with an ultra-wideband Fourier-domain mode-locked laser at MHz A-scan rates.

Authors:  Jan Philip Kolb; Tom Pfeiffer; Matthias Eibl; Hubertus Hakert; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-12-05       Impact factor: 3.732

4.  Characterization and Analysis of Relative Intensity Noise in Broadband Optical Sources for Optical Coherence Tomography.

Authors:  Sunghwan Shin; Utkarsh Sharma; Haohua Tu; Woonggyu Jung; Stephen A Boppart
Journal:  IEEE Photonics Technol Lett       Date:  2010       Impact factor: 2.468

5.  Numerical calibration method for a multiple spectrometer-based OCT system.

Authors:  Yusi Miao; Jun Song; Destiny Hsu; Ringo Ng; Yifan Jian; Marinko V Sarunic; Myeong Jin Ju
Journal:  Biomed Opt Express       Date:  2022-02-24       Impact factor: 3.732

6.  Reference spectrum extraction and fixed-pattern noise removal in optical coherence tomography.

Authors:  Sucbei Moon; Sang-Won Lee; Zhongping Chen
Journal:  Opt Express       Date:  2010-11-22       Impact factor: 3.894

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.