Literature DB >> 1544791

Computerized analysis of pupillograms in studies of alertness.

J W McLaren1, J C Erie, R F Brubaker.   

Abstract

When alert subjects sit in a quiet, darkened room for 10-15 min, their pupils remain dilated. If the subjects become sleepy or fatigued, their pupils become miotic and oscillate. Pupillometry, the recording of pupil diameter, has been used to study alertness. Pupillograms are typically graded by subjective assessment on the basis of oscillations of pupil diameter (hippus) and miosis. In this study, numeric parameters were calculated from pupillograms and were compared to subjective ratings by clinicians. Pupil diameters were recorded for 15 min at five samples per second with a custom built video pupillometer. Subjects sat in the dark and fixated a small red light. Digital filtering techniques and Fourier analysis were used to calculate several parameters designed to report hippus and miosis. The same set of pupillograms was graded by three physicians familiar with pupillometry. Grades were assigned on a scale of 1 to 4, 1 being most alert and 4 least alert. A linear combination of three of the numeric parameters had the highest correlation with the average subjective grade (r = 0.92). These techniques provide a quantitative way to evaluate pupillograms that will be used in the assessment of alertness.

Entities:  

Mesh:

Year:  1992        PMID: 1544791

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  11 in total

Review 1.  Vigilance, alertness, or sustained attention: physiological basis and measurement.

Authors:  B S Oken; M C Salinsky; S M Elsas
Journal:  Clin Neurophysiol       Date:  2006-04-03       Impact factor: 3.708

Review 2.  A locus coeruleus-norepinephrine account of individual differences in working memory capacity and attention control.

Authors:  Nash Unsworth; Matthew K Robison
Journal:  Psychon Bull Rev       Date:  2017-08

3.  Suppression of pupillary unrest by general anesthesia and propofol sedation.

Authors:  Matthias Behrends; Merlin D Larson; Andrew E Neice; Michael P Bokoch
Journal:  J Clin Monit Comput       Date:  2018-05-21       Impact factor: 2.502

4.  Individual differences in baseline oculometrics: Examining variation in baseline pupil diameter, spontaneous eye blink rate, and fixation stability.

Authors:  Nash Unsworth; Matthew K Robison; Ashley L Miller
Journal:  Cogn Affect Behav Neurosci       Date:  2019-08       Impact factor: 3.282

5.  Pupil responses to near visual demand during human visual development.

Authors:  Shrikant R Bharadwaj; Jingyun Wang; T Rowan Candy
Journal:  J Vis       Date:  2011-04-11       Impact factor: 2.240

6.  Identification of attention-deficit hyperactivity disorder based on the complexity and symmetricity of pupil diameter.

Authors:  Sou Nobukawa; Aya Shirama; Tetsuya Takahashi; Toshinobu Takeda; Haruhisa Ohta; Mitsuru Kikuchi; Akira Iwanami; Nobumasa Kato; Shigenobu Toda
Journal:  Sci Rep       Date:  2021-04-19       Impact factor: 4.379

Review 7.  Physiological recordings: basic concepts and implementation during functional magnetic resonance imaging.

Authors:  Marcus A Gray; Ludovico Minati; Neil A Harrison; Peter J Gianaros; Vitaly Napadow; Hugo D Critchley
Journal:  Neuroimage       Date:  2009-05-19       Impact factor: 6.556

8.  Oculometric variations during mind wandering.

Authors:  Romain Grandchamp; Claire Braboszcz; Arnaud Delorme
Journal:  Front Psychol       Date:  2014-02-11

9.  Investigation of nonlinear pupil dynamics by recurrence quantification analysis.

Authors:  L Mesin; A Monaco; R Cattaneo
Journal:  Biomed Res Int       Date:  2013-09-26       Impact factor: 3.411

10.  Human Auditory Detection and Discrimination Measured with the Pupil Dilation Response.

Authors:  Avinash D S Bala; Elizabeth A Whitchurch; Terry T Takahashi
Journal:  J Assoc Res Otolaryngol       Date:  2019-12-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.