Sensitivity of the knee joint kinematics calculation to selection of flexion axes.

E Most1, J Axe, H Rubash, G Li.   

Abstract

Various flexion axes have been used in the literature to describe knee joint kinematics. This study measured the passive knee kinematics of six cadaveric human knee specimens using two widely accepted flexion axes; transepicondylar axis and the geometric center axis. These two axes were found to form an angle of 4.0 degrees +/- 0.8 degrees. The tibial rotation calculated using the transepicondylar axis was significantly different than the rotation obtained using the geometric center axis for the same knee motion. At 90 degrees of flexion, the tibial rotation obtained using the transepicondylar axis was 4.8 degrees +/- 9.4 degrees whereas the rotation recorded using the geometric center axis at the same flexion angle was 13.8 degrees +/- 10.2 degrees. At 150 degrees of knee flexion, the rotations obtained from the transepicondylar and the geometric center axes were 7.2 degrees +/- 5.7 degrees and 19.9 degrees +/- 6.9 degrees, respectively. The data suggest that a clear definition of the flexion axis is necessary when reporting knee joint kinematics.

Entities:  

Mesh:

Year:  2004        PMID: 15388317     DOI: 10.1016/j.jbiomech.2004.01.025

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  37 in total

1.  Three-dimensional in vivo motion analysis of normal knees employing transepicondylar axis as an evaluation parameter.

Authors:  Osamu Tanifuji; Takashi Sato; Koichi Kobayashi; Tomoharu Mochizuki; Yoshio Koga; Hiroshi Yamagiwa; Go Omori; Naoto Endo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-28       Impact factor: 4.342

2.  3D inverse dynamics in non-orthonormal segment coordinate system.

Authors:  R Dumas; L Chèze
Journal:  Med Biol Eng Comput       Date:  2007-01-25       Impact factor: 2.602

3.  Knee functional flexion axis in osteoarthritic patients: comparison in vivo with transepicondylar axis using a navigation system.

Authors:  F Colle; S Bignozzi; N Lopomo; S Zaffagnini; L Sun; M Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-14       Impact factor: 4.342

4.  Moment arms of the knee extensor mechanism in children and adults.

Authors:  Thomas D O'Brien; Neil D Reeves; Vasilios Baltzopoulos; David A Jones; Constantinos N Maganaris
Journal:  J Anat       Date:  2009-06-01       Impact factor: 2.610

5.  A comparison of different two-dimensional approaches for the determination of the patellar tendon moment arm length.

Authors:  Dimitrios E Tsaopoulos; Vasilios Baltzopoulos; Paula J Richards; Constantinos N Maganaris
Journal:  Eur J Appl Physiol       Date:  2009-01-06       Impact factor: 3.078

6.  The effect of geometric variations in posterior-stabilized knee designs on motion characteristics measured in a knee loading machine.

Authors:  Peter S Walker; Michael T Lowry; Anoop Kumar
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

7.  Kinematics of the knee after unicompartmental arthroplasty is not the same as normal and is similar to the kinematics of the knee with osteoarthritis.

Authors:  Tomoharu Mochizuki; Takashi Sato; John David Blaha; Osamu Tanifuji; Koichi Kobayashi; Hiroshi Yamagiwa; Satoshi Watanabe; Munenori Matsueda; Yoshio Koga; Go Omori; Naoto Endo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-11-12       Impact factor: 4.342

8.  The vector of quadriceps pull is directed from the patella to the femoral neck.

Authors:  Osamu Tanifuji; John David Blaha; Shin Kai
Journal:  Clin Orthop Relat Res       Date:  2012-12-20       Impact factor: 4.176

9.  In vivo patellar tracking and patellofemoral cartilage contacts during dynamic stair ascending.

Authors:  Takashi Suzuki; Ali Hosseini; Jing-Sheng Li; Thomas J Gill; Guoan Li
Journal:  J Biomech       Date:  2012-07-26       Impact factor: 2.712

10.  Tibiofemoral kinematics and condylar motion during the stance phase of gait.

Authors:  Michal Kozanek; Ali Hosseini; Fang Liu; Samuel K Van de Velde; Thomas J Gill; Harry E Rubash; Guoan Li
Journal:  J Biomech       Date:  2009-06-03       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.