Literature DB >> 15387034

Nonextraction treatment with microscrew implants.

Hyo-Sang Park1, Tae-Geon Kwon, Jae-Hyun Sung.   

Abstract

The maxillary and mandibular posterior teeth were retracted with microscrew implants (1.2 mm in diameter and six to 10 mm long) that were placed into the alveolar bone and used as anchorage. The retraction proceeded without adverse reciprocal effects on the reactive part of the conventional mechanics, such as premolar extrusion and flaring of the incisors. The anterior crowding was resolved without any deleterious effect on the facial profile. En masse movement of the posterior teeth and the whole dentition after anterior tooth alignment can reducethe treatment period and maximize the efficiency of the treatment. The microscrew implants were maintained firmly throughout the treatment and were able to provide an anchorage for retraction of whole dentitions. The efficacy and potency of the microscrew implants aid mechanics in the nonextraction treatment of both labial and lingual treatments.

Mesh:

Substances:

Year:  2004        PMID: 15387034     DOI: 10.1043/0003-3219(2004)074<0539:NTWMI>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  15 in total

1.  Maxillary molar distalization with first class appliance.

Authors:  Namitha Ramesh; Biswas Palukunnu; Nidhi Ravindran; Preeti P Nair
Journal:  BMJ Case Rep       Date:  2014-02-27

2.  Buccal cortical bone thickness at miniscrew placement sites in patients with different vertical skeletal patterns.

Authors:  Ilknur Veli; Tancan Uysal; Asli Baysal; Irfan Karadede
Journal:  J Orofac Orthop       Date:  2014-10-26       Impact factor: 1.938

3.  Mechanical stability assessment of novel orthodontic mini-implant designs: Part 2.

Authors:  Christine Hong; Peter Truong; Ha Na Song; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-06-29       Impact factor: 2.079

4.  Comparison of cytokine level changes in gingival crevicular fluid between the aligner and pendulum appliance during early molar distalization : A single-center, prospective, observational study.

Authors:  Huijuan Chen; Liuhui Liu; Yuan Li; Lingyun Guo; Dongmei Sun
Journal:  J Orofac Orthop       Date:  2021-10-22       Impact factor: 1.938

5.  Patients' and orthodontists' perceptions of miniplates used for temporary skeletal anchorage: a prospective study.

Authors:  Marie A Cornelis; Nicole R Scheffler; Catherine Nyssen-Behets; Hugo J De Clerck; J F Camilla Tulloch
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-01       Impact factor: 2.650

6.  A comparison of second premolar extraction and mini-implant total arch distalization with interproximal stripping.

Authors:  Min-Ho Jung
Journal:  Angle Orthod       Date:  2012-11-30       Impact factor: 2.079

7.  Use of the intraosseous screw for unilateral upper molar distalization and found well balanced occlusion.

Authors:  Ibrahim Erhan Gelgor; Ali Ihya Karaman; Tamer Buyukyilmaz
Journal:  Head Face Med       Date:  2006-11-09       Impact factor: 2.151

8.  Distalization pattern of whole maxillary dentition according to force application points.

Authors:  Eui-Hyang Sung; Sung-Jin Kim; Youn-Sic Chun; Young-Chel Park; Hyung-Seog Yu; Kee-Joon Lee
Journal:  Korean J Orthod       Date:  2015-01-26       Impact factor: 1.372

9.  Class II correction by maxillary en masse distalization using a completely customized lingual appliance and a novel mini-screw anchorage concept - preliminary results.

Authors:  Frauke Beyling; Elisabeth Klang; Eva Niehoff; Rainer Schwestka-Polly; Hans-Joachim Helms; Dirk Wiechmann
Journal:  Head Face Med       Date:  2021-06-29       Impact factor: 2.151

10.  Three-dimensional analysis of the distal movement of maxillary 1st molars in patients fitted with mini-implant-aided trans-palatal arches.

Authors:  Amirfarhang Miresmaeili; Ahmad Sajedi; Abbas Moghimbeigi; Nasrin Farhadian
Journal:  Korean J Orthod       Date:  2015-09-23       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.