Abstract

While polypropylene mesh remains the preferred prosthesis material for hernioplasties, there are some problems with infections, intestinal obstruction and fistulization, and migration particularly in immunodepressed patients. A new degradable and reabsorbable material, the porcine small intestinal submucosa (Surgisis) has been developed for hernia repairs in humans. This prospective study evaluated the safety and efficacy of Lichtenstein hernioplasty using the Surgisis inguinal hernia matrix soft-tissue graft as a mesh in ten immunodepressed subjects. Six subjects were HIV-positive in the immunodepressive phase, and the other four had undergone transplantation (three kidney, one liver). There were no intraoperative or postoperative complications, recurrences, or wound infections. Thus Lichtenstein's hernioplasty using the Surgisis inguinal hernia matrix soft-tissue graft in immunodepressed patients promises safety and efficacy.

Entities:  

Mesh:

Year:  2004        PMID: 15378399     DOI: 10.1007/s10029-004-0273-y

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  25 in total

1.  [Concerning "Intraperitoneal polyglactin 910 absorbable prosthesis: a risk-free preventive method?"].

Authors:  J F Rodier
Journal:  Ann Chir       Date:  1999

2.  A biodegradeable membrane from porcine intestinal submucosa to reinforce the gastrojejunostomy in laparoscopic Roux-en-Y gastric bypass: preliminary report.

Authors:  S Kini; M Gagner; J de Csepel; P Gentileschi; G Dakin
Journal:  Obes Surg       Date:  2001-08       Impact factor: 4.129

3.  Retention of endothelial cell adherence to porcine-derived extracellular matrix after disinfection and sterilization.

Authors:  Jason P Hodde; Rae D Record; Robert S Tullius; Stephen F Badylak
Journal:  Tissue Eng       Date:  2002-04

Review 4.  The Lichtenstein repair in 2002: an overview of causes of recurrence after Lichtenstein tension-free hernioplasty.

Authors:  P K Amid
Journal:  Hernia       Date:  2002-10-05       Impact factor: 4.739

5.  Small intestinal submucosa as a small-diameter arterial graft in the dog.

Authors:  G C Lantz; S F Badylak; A C Coffey; L A Geddes; W E Blevins
Journal:  J Invest Surg       Date:  1990       Impact factor: 2.533

6.  Xenogeneic extracellular matrix grafts elicit a TH2-restricted immune response.

Authors:  A J Allman; T B McPherson; S F Badylak; L C Merrill; B Kallakury; C Sheehan; R H Raeder; D W Metzger
Journal:  Transplantation       Date:  2001-06-15       Impact factor: 4.939

7.  Strength over time of a resorbable bioscaffold for body wall repair in a dog model.

Authors:  S Badylak; K Kokini; B Tullius; B Whitson
Journal:  J Surg Res       Date:  2001-08       Impact factor: 2.192

8.  Preliminary experience with new bioactive prosthetic material for repair of hernias in infected fields.

Authors:  M E Franklin; J J Gonzalez; R P Michaelson; J L Glass; D A Chock
Journal:  Hernia       Date:  2002-10-19       Impact factor: 4.739

9.  Ureteral segmental replacement using multilayer porcine small-intestinal submucosa.

Authors:  Mario Sofer; Elaine Rowe; Dale M Forder; John D Denstedt
Journal:  J Endourol       Date:  2002-02       Impact factor: 2.942

10.  Intestine submucosa and polypropylene mesh for abdominal wall repair in dogs.

Authors:  K M Clarke; G C Lantz; S K Salisbury; S F Badylak; M C Hiles; S L Voytik
Journal:  J Surg Res       Date:  1996-01       Impact factor: 2.192

View more
  17 in total

1.  Use of porcine dermal collagen graft (Permacol) for hernia repair in contaminated fields.

Authors:  F Catena; L Ansaloni; F Gazzotti; S Gagliardi; S Di Saverio; L D'Alessandro; A D Pinna
Journal:  Hernia       Date:  2006-11-21       Impact factor: 4.739

2.  Adverse effects of porcine small intestine submucosa (SIS) implants in experimental ventral hernia repair.

Authors:  F Catena; L Ansaloni; L D'Alessandro; A Pinna
Journal:  Surg Endosc       Date:  2006-12-16       Impact factor: 4.584

Review 3.  Immune response to biologic scaffold materials.

Authors:  Stephen F Badylak; Thomas W Gilbert
Journal:  Semin Immunol       Date:  2008-02-20       Impact factor: 11.130

4.  Quantification of DNA in biologic scaffold materials.

Authors:  Thomas W Gilbert; John M Freund; Stephen F Badylak
Journal:  J Surg Res       Date:  2008-03-13       Impact factor: 2.192

5.  Biologic hernia implants in experimental intraperitoneal onlay mesh plasty repair: the impact of proprietary collagen processing methods and fibrin sealant application on tissue integration.

Authors:  A H Petter-Puchner; R H Fortelny; K Silic; J Brand; S Gruber-Blum; H Redl
Journal:  Surg Endosc       Date:  2011-04-30       Impact factor: 4.584

6.  Abdominal wall reconstruction by combined use of biological mesh and autogenous pedicled demucosalized small intestinal sheet: a case report.

Authors:  Y Wu; J Ren; S Liu; G Han; Y Zhao; J Li
Journal:  Hernia       Date:  2012-07-21       Impact factor: 4.739

7.  Prosthetic abdominal wall hernia repair in emergency surgery: from polypropylene to biological meshes.

Authors:  G Campanelli; F Catena; L Ansaloni
Journal:  World J Emerg Surg       Date:  2008-12-04       Impact factor: 5.469

8.  The use of porcine small intestinal submucosa as a prosthetic material for laparoscopic hernia repair in infected and potentially contaminated fields: long-term follow-up.

Authors:  Morris E Franklin; Jorge M Treviño; Guillermo Portillo; Itzel Vela; Jeffrey L Glass; John J González
Journal:  Surg Endosc       Date:  2008-07-02       Impact factor: 4.584

9.  New "biological" meshes: the need for a register. The EHS Registry for Biological Prostheses: call for participating European surgeons.

Authors:  L Ansaloni; F Catena; F Coccolini; P Negro; G Campanelli; M Miserez
Journal:  Hernia       Date:  2008-10-23       Impact factor: 4.739

10.  Abdominal wall defect repair with biological prosthesis in transplanted patients: single center retrospective analysis and review of the literature.

Authors:  Federico Coccolini; Fausto Catena; Valentina R Bertuzzo; Giorgio Ercolani; Antonio Pinna; Luca Ansaloni
Journal:  Updates Surg       Date:  2013-05-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.