Literature DB >> 15378194

Molar distalization with different pendulum appliances: in vitro registration of orthodontic forces and moments in the initial phase.

Gero Kinzinger1, Christian Syrée, Ulrike Fritz, Peter Diedrich.   

Abstract

AIM: Registration of the orthodontic forces and moments acting with different types of pendulum appliance for non-compliance upper molar distalization in an in vitro study.
MATERIAL AND METHODS: The purpose-designed test set-up comprised the following components: artificial maxilla with anchorage unit and two electrothermodynamic (ETD) molars, electronic measuring unit for temperature control and regulation, and a sensor unit with force-moment sensor, analog/digital converter and data readout unit. This set-up permitted virtually authentic simulation of in vivo conditions on the one hand and precise determination of the force systems on the other. The appliances investigated were the standard pendulum appliance with U-loop activation according to Hilgers and with uprighting activation according to Byloff, the M-pendulum with U-loop activation according to Scuzzo, and the Pendulum K with initial uprighting activation, toe-in bend and incorporated distal screw according to Kinzinger. RESULTS AND
CONCLUSIONS: The effects shown by the standard pendulum appliance and the M-pendulum over a 3 mm simulated distalization increment were a marked decrease in the distally directed forces, and an increase in the intrusive and palatally directed forces as well as in the distoinclinatory, mesially inward, and palatally rotating moments. Activations in the U-loop region of the pendulum springs induced an increase in distally and buccally directed forces and in uprighting and buccally rotating moments as well as a marked rise in extrusive forces. Whereas the activation described by Hilgers led to mesially outward rotating moments, activation according to Scuzzo resulted in a further increase in the mesially inward rotating moments. In the measured standard pendulum appliances, uprighting activation at the end of the pendulum according to Byloff led to an increase in distally and buccally directed as well as in mildly intrusive forces, and to an increase in uprighting as well as in buccally and mesially outward rotating moments. With the Pendulum K according to Kinzinger, the initial toe-in bend and uprighting activation in the region of the end of the pendulum spring together with regular adjustment of the incorporated distal screw permitted virtually translatory molar distalization: constantly distalizing forces with slight intrusive, buccally directed, and rotating side effects.

Mesh:

Year:  2004        PMID: 15378194     DOI: 10.1007/s00056-004-0406-z

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  6 in total

1.  Effects of conventional anchorage on premolar root development during treatment with a pendulum appliance.

Authors:  Gero Kinzinger; Cora Pantel; Björn Ludwig; Norbert Gülden; Bettina Glasl; Jörg Lisson
Journal:  J Orofac Orthop       Date:  2010-07-30       Impact factor: 1.938

2.  Occlusal Plane Changes After Molar Distalization With a Pendulum Appliance in Growing Patients with Class II Malocclusion: A Retrospective Cephalometric Study.

Authors:  Marco Serafin; Rosamaria Fastuca; Elisabetta Castellani; Alberto Caprioglio
Journal:  Turk J Orthod       Date:  2021-02-23

3.  Management of a Periodontal Pocket Using a Removable Orthodontic Appliance and Nonsurgical Periodontal Therapy.

Authors:  Serhat Köseoğlu; Ahmet Fidancıoğlu; Mehmet Sağlam; Levent Savran
Journal:  Case Rep Dent       Date:  2015-09-03

4.  Cone-beam computed tomography-guided three-dimensional evaluation of treatment effectiveness of the Frog appliance.

Authors:  Mujia Li; Xiaoxia Su; Yang Li; Xianglin Li; Xinqin Si
Journal:  Korean J Orthod       Date:  2019-05-21       Impact factor: 1.372

5.  Establishment, FEM analysis and experimental validation of tooth movement prediction model of orthodontic archwire T-loop.

Authors:  Jingang Jiang; Liang Yao; Yongde Zhang; Xuefeng Ma; Yafeng Guo; Yi Liu
Journal:  BMC Oral Health       Date:  2022-09-17       Impact factor: 3.747

6.  Efficiency of the skeletonized Pendulum K appliance for non-compliance maxillary molar distalization : A clinical pilot study.

Authors:  Gero Stefan Michael Kinzinger; Jan Hourfar; Jörg Alexander Lisson
Journal:  J Orofac Orthop       Date:  2021-03-02       Impact factor: 1.938

  6 in total