ELF magnetic field exposure in a neonatal intensive care unit.

Cristiano Riminesi1, Daniele Andreuccetti, Roberto Fossi, Marco Pezzati.   

Abstract

In this paper, the magnetic flux density (MFD) distribution in a neonatal intensive care unit is described and MFD values inside a few open infant warming systems and incubators are reported. Typical measured values of the magnetic flux density at power frequency (50 Hz) in the "general environment" (the rooms of the unit) were lower than 0.2 microT, while higher MFD values were detected close to medical equipment and inside the open infant warming systems. In both cases, the magnetic flux density quickly decreases with increasing distance, so that measured values are reduced to "background" (i.e., general environment) levels 20-30 cm away from the sources. The total harmonic content over the 100-800 Hz frequency range was also evaluated. In the general environment, measured values in this band were negligible, while this was not the case close to medical equipment. Field levels inside the open and closed incubators depend on the position of the electronic control system, of the heating power generator and its winding conductor, and of the 220 V main plug. The magnetic flux density was also monitored for a prolonged period of time in a few types of open infant warming systems and incubators under standard intensive care unit operation with premature newborn present. 2004 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2004        PMID: 15376248     DOI: 10.1002/bem.20017

Source DB:  PubMed          Journal:  Bioelectromagnetics        ISSN: 0197-8462            Impact factor:   2.010


  5 in total

1.  Analyzing Exposures to Electromagnetic Fields in an Intensive Care Unit.

Authors:  Necati Gökmen; Sabri Erdem; Kadir Atilla Toker; Elvan Öçmen; Başak Ilgım Gökmen; Ahmet Özkurt
Journal:  Turk J Anaesthesiol Reanim       Date:  2016-10-01

2.  Electrical Grounding Improves Vagal Tone in Preterm Infants.

Authors:  Rohit Passi; Kim K Doheny; Yuri Gordin; Hans Hinssen; Charles Palmer
Journal:  Neonatology       Date:  2017-06-10       Impact factor: 4.035

3.  Exposure of surgeons to extremely low-frequency magnetic fields during laparoscopic and robotic surgeries.

Authors:  Jee Soo Park; Jai Won Chung; Nam Kyu Kim; Min Soo Cho; Chang Moo Kang; Soo Beom Choi; Deok Won Kim
Journal:  Medicine (Baltimore)       Date:  2015-02       Impact factor: 1.889

4.  Evaluation of the electromagnetic field intensity in operating rooms and estimation of occupational exposures of personnel.

Authors:  Karim Ghazikhanlou-Sani; Azizollah Rahimi; Maryam Poorkaveh; Samira Eynali; Fereshteh Koosha; Mohsen Shoja
Journal:  Interv Med Appl Sci       Date:  2018-09

5.  Safety of Exposure From Extremely Low Frequency Magnetic Fields During Prenatal Ultrasound Examinations in Clinicians and Pregnant Women.

Authors:  Jee Soo Park; Deok Won Kim; Jai Won Chung; Ja-Young Kwon; Yong Won Park; Hee Young Cho
Journal:  Medicine (Baltimore)       Date:  2015-07       Impact factor: 1.817