Literature DB >> 15364839

Magnetic Vascular Port in minimally invasive direct coronary artery bypass grafting.

Uwe Klima1, Horace MacVaugh, Eric Bagaev, Michael Maringka, S Kirschner, J Beilner, Axel Haverich.   

Abstract

BACKGROUND: Minimally invasive direct coronary artery bypass grafting (MIDCAB) is a well-established operative procedure. However, it is technically demanding and is therefore somewhat underused. We evaluated the clinical and angiographic outcome of patients undergoing a MIDCAB procedure with the Ventrica Magnetic Vascular Port (MVP) system. METHODS AND
RESULTS: A Ventrica MVP system was used in 10 of 11 selected MIDCAB patients. The system consists of 6 magnetic clips, with 3 clips forming a set. One magnetic clip set is positioned at the arteriotomy of the target artery and of the bypass graft using a preloaded delivery system. These ports then form an anastomosis by magnetic coupling. The mean age of the 10 patients (6 male) was 60.3+/-11.0 years. Three patients had an angiogram at the time of discharge and 8 returned for a 6-month angiogram. The total procedure time was 128.2+/-12.2 minutes. The mean anastomotic time was 199 seconds. The mean ischemic time during the anastomosis was 146+/-146 seconds. There were no in-hospital complications and no device-related adverse events. All 3 predischarge and all 8 6-month angiograms showed patent anastomoses.
CONCLUSIONS: The magnetic vascular port facilitates the MIDCAB procedure significantly and reduces the ischemic time during the anastomosis. This minimally invasive procedure has the potential to be an alternative to percutaneous transluminal coronary angioplasty and stenting in proximal left anterior descending (LAD) stenosis. It may expand the acceptance of hybrid procedures in which a left internal mammary artery (LIMA)-to-LAD graft optimally supplies the anterior wall and the septum while the circumflex and right coronary artery may be treated interventionally.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15364839     DOI: 10.1161/01.CIR.0000138391.77285.d9

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

1.  Magnetic Anastomosis Rings to Create Portacaval Shunt in a Canine Model of Portal Hypertension.

Authors:  Hao-Hua Wang; Jia Ma; Shan-Pei Wang; Feng Ma; Jian-Wen Lu; Xiang-Hua Xu; Yi Lv; Xiao-Peng Yan
Journal:  J Gastrointest Surg       Date:  2018-08-21       Impact factor: 3.452

2.  A sutureless method for digestive tract reconstruction during pancreaticoduodenectomy in a dog model.

Authors:  Xiaohai Cui; Peng Lei; Shiqi Liu; Xuemin Liu; Zheng Wu; Yi Lv
Journal:  Int J Clin Exp Med       Date:  2015-01-15

3.  Extrahepatic portacaval shunt via a magnetic compression technique: A cadaveric feasibility study.

Authors:  Xiao-Peng Yan; Wen-Yan Liu; Jia Ma; Jian-Peng Li; Yi Lv
Journal:  World J Gastroenterol       Date:  2015-07-14       Impact factor: 5.742

4.  Novel magnetic compression technique for establishment of a canine model of tracheoesophageal fistula.

Authors:  Yi Gao; Rong-Qian Wu; Yi Lv; Xiao-Peng Yan
Journal:  World J Gastroenterol       Date:  2019-08-14       Impact factor: 5.742

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.