Literature DB >> 15362269

An on line technique to detect cardiac output variations and cardiovascular performances during abdominal aortic surgery.

Fabrizio Clemente1, Emilio D'Avino, Marco Guaragno, Antonio Menichetti.   

Abstract

Cardiac output (CO) is a parameter usually requested to assess hemo dynamic status of patient and efficacy of therapy especially in critically ill patients. This paper, in line with other research activities and new market availability, intends to correlate a parameter derived from data already acquired in standard patient monitoring (systemic arterial pressure--Pas) in order to identify CO trends and, more generally, to obtain information on the efficiency of cardiovascular system of the patient in examination. Attention has been focussed on patients undergoing abdominal aneurysm aortic (AAA) surgery with combined anaesthesia (epidural and light general). Awake correlation was found between maximum value of Pas time derivative, max (dPas/dt), and CO measured with thermodilution method on 56 measurements on 10 patients. To evaluate further diagnostic capability of max (dPas/dt), we compare its trend with other parameters but no statistical significant results have been obtained. Therefore the target parameter can be profitably used in the examined patients to monitor CO trend and, in correlation with other parameters, as a sign of efficiency of the cardio circulatory system.

Entities:  

Mesh:

Year:  2004        PMID: 15362269     DOI: 10.1023/b:jocm.0000032696.16467.3d

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  11 in total

1.  The (dP/dt)max derived from arterial pulse waveforms: prospective applications in the haemodialysis setting.

Authors:  J Kyriazis; J Glotsos; L Bilirakis; N Smirnioudis
Journal:  Nephrol Dial Transplant       Date:  2001-05       Impact factor: 5.992

2.  A virtual instrument (VI) for haemodynamic management in ICU and during surgery.

Authors:  F Clemente; M Antonini; C De Lazzari; G Ferrari; R Mimmo; M Guaragno; G Tosti
Journal:  J Med Eng Technol       Date:  2000 May-Jun

3.  Study of systolic pressure variation (SPV) in presence of mechanical ventilation.

Authors:  F Clemente; C De Lazzari; M Darowski; G Ferrari; R Mimmo; M Guaragno; G Tosti
Journal:  Int J Artif Organs       Date:  2002-04       Impact factor: 1.595

4.  Continuous cardiac output in septic shock by simulating a model of the aortic input impedance: a comparison with bolus injection thermodilution.

Authors:  W T Jellema; K H Wesseling; A B Groeneveld; C P Stoutenbeek; L G Thijs; J J van Lieshout
Journal:  Anesthesiology       Date:  1999-05       Impact factor: 7.892

5.  Development and validation of a noninvasive method to determine arterial pressure and vascular compliance.

Authors:  T J Brinton; B Cotter; M T Kailasam; D L Brown; S S Chio; D T O'Connor; A N DeMaria
Journal:  Am J Cardiol       Date:  1997-08-01       Impact factor: 2.778

6.  Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform.

Authors:  R Pizov; M Cohen; Y Weiss; E Segal; S Cotev; A Perel
Journal:  Crit Care Med       Date:  1996-08       Impact factor: 7.598

7.  Clinical evaluation of a partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients.

Authors:  H Odenstedt; O Stenqvist; S Lundin
Journal:  Acta Anaesthesiol Scand       Date:  2002-02       Impact factor: 2.105

8.  The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators.

Authors:  A F Connors; T Speroff; N V Dawson; C Thomas; F E Harrell; D Wagner; N Desbiens; L Goldman; A W Wu; R M Califf; W J Fulkerson; H Vidaillet; S Broste; P Bellamy; J Lynn; W A Knaus
Journal:  JAMA       Date:  1996-09-18       Impact factor: 56.272

9.  Noninvasive cardiac output assessment during heart surgery.

Authors:  Piero Ceriana; Marco Mau Relli; Antonio Braschi; Paola Baiardi; Donatella De Amici
Journal:  J Clin Monit Comput       Date:  2002-02       Impact factor: 2.502

Review 10.  Equipment review: new techniques for cardiac output measurement--oesophageal Doppler, Fick principle using carbon dioxide, and pulse contour analysis.

Authors:  Christine Berton; Bernard Cholley
Journal:  Crit Care       Date:  2002-04-25       Impact factor: 9.097

View more