Literature DB >> 15357407

Tinnitus and cochlear implantation.

Nicola Quaranta1, Sherryl Wagstaff, David M Baguley.   

Abstract

Tinnitus is a common experience, but there is very marked heterogeneity of aetiology, perception and the extent of distress among individuals who experience tinnitus. In view of this, a modern approach to tinnitus should consider homogeneous groups of individuals. This review considers tinnitus experiences in patients undergoing cochlear implantation, this being of interest because the prevalence of tinnitus in this patient group prior to surgery may shed some light on the link between cochlear dysfunction and tinnitus Second, any change in tinnitus experience as a result of electrode placement surgery or cochlear implant activation has relevance for patient counselling and informed consent. Finally, in recent tinnitus retraining therapy literature there has been the suggestion that unilateral sound therapy for tinnitus patients may set up an unhelpful asymmetry of input to the auditory system, with possible exacerbation of contralateral tinnitus. Unilateral cochlear implant use represents the most dramatic asymmetry possible and hence is a test of that hypothesis. Relevant papers (n = 32) were identified from literature databases. The standard of reporting tinnitus results was inconsistent. Tinnitus is experienced by up to 86% of adult cochlear implant candidates, but is not universal and is only troublesome in a small proportion (reported as 27% in one study). Electrode insertion may induce tinnitus in a small (up to 4%) number of patients, but this is rare. Cochlear implant device use is associated with reduction of tinnitus intensity and awareness in up to 86% of patients, and rarely with exacerbation (up to 9%). There are some indications in the literature that the more complex the simulation strategy, the larger that effect. Specifically, unilateral cochlear implant use was generally associated with reduction of contralateral tinnitus (in up to 67% of individuals) rather than exacerbation, and so the assertion that unilateral sound therapy for tinnitus is contraindicated is not proven.

Entities:  

Mesh:

Year:  2004        PMID: 15357407     DOI: 10.1080/14992020400050033

Source DB:  PubMed          Journal:  Int J Audiol        ISSN: 1499-2027            Impact factor:   2.117


  33 in total

1.  Electrical Stimulation of the Cochlea to Reduce Tinnitus.

Authors:  Richard S Tyler; Jay Rubinstein; Tao Pan; Son-A Chang; Stephanie A Gogel; Anne Gehringer; Claudia Coelho
Journal:  Semin Hear       Date:  2008-11

2.  A Series of Case Studies of Tinnitus Suppression With Mixed Background Stimuli in a Cochlear Implant.

Authors:  Richard S Tyler; A J Keiner; Kurt Walker; Aniruddha K Deshpande; Shelley Witt; Matthijs Killian; Helena Ji; Jim Patrick; Norbert Dillier; Pim van Dijk; Wai Kong Lai; Marlan R Hansen; Bruce Gantz
Journal:  Am J Audiol       Date:  2015-09       Impact factor: 1.493

3.  Quality of life and audiologic performance through the ability to phone of cochlear implant users.

Authors:  Cécile Rumeau; Julien Frère; Bettina Montaut-Verient; Alexis Lion; Gérome Gauchard; Cécile Parietti-Winkler
Journal:  Eur Arch Otorhinolaryngol       Date:  2014-12-20       Impact factor: 2.503

4.  A multidisciplinary European guideline for tinnitus: diagnostics, assessment, and treatment.

Authors:  R F F Cima; B Mazurek; H Haider; D Kikidis; A Lapira; A Noreña; D J Hoare
Journal:  HNO       Date:  2019-03       Impact factor: 1.284

5.  [Hearing aids, implantable hearing aids and cochlear implants in chronic tinnitus therapy].

Authors:  H Olze; T Zahnert; G Hesse
Journal:  HNO       Date:  2010-10       Impact factor: 1.284

6.  One-Year Results for Patients with Unilateral Hearing Loss and Accompanying Severe Tinnitus and Hyperacusis Treated with a Cochlear Implant.

Authors:  Angel Ramos Macías; Juan Carlos Falcón-González; Manuel Manrique Rodríguez; Constantino Morera Pérez; Luis García-Ibáñez; Carlos Cenjor Español; Chrystelle Coudert-Koall; Matthijs Killian
Journal:  Audiol Neurootol       Date:  2018-06-21       Impact factor: 1.854

7.  [Cochlear implants and tinnitus].

Authors:  H Olze
Journal:  HNO       Date:  2015-04       Impact factor: 1.284

8.  [Unilateral deafness and cochlear implantation: audiological diagnostic evaluation and outcomes].

Authors:  S Arndt; R Laszig; A Aschendorff; R Beck; C Schild; F Hassepass; G Ihorst; S Kroeger; P Kirchem; T Wesarg
Journal:  HNO       Date:  2011-05       Impact factor: 1.284

9.  [Present state of cochlear implant treatment in adults and children].

Authors:  J Maurer
Journal:  HNO       Date:  2009-07       Impact factor: 1.284

10.  Changes in the tinnitus handicap questionnaire after cochlear implantation.

Authors:  Tao Pan; Richard S Tyler; Haihong Ji; Claudia Coelho; Anne K Gehringer; Stephanie A Gogel
Journal:  Am J Audiol       Date:  2009-12       Impact factor: 1.493

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.