Literature DB >> 1535570

Lumen diameter of normal human coronary arteries. Influence of age, sex, anatomic variation, and left ventricular hypertrophy or dilation.

J T Dodge1, B G Brown, E L Bolson, H T Dodge.   

Abstract

BACKGROUND: Precise knowledge of the expected "normal" lumen diameter at a given coronary anatomic location is a first step toward developing a quantitative estimate of coronary disease severity that could be more useful than the traditional "percent stenosis." METHODS AND
RESULTS: Eighty-three arteriograms were carefully selected from among 9,160 consecutive studies for their smooth lumen borders indicating freedom from atherosclerotic disease. Of these, 60 men and 10 women had no abnormalities of cardiac function, seven men had idiopathic dilated cardiomyopathy, and six men had left ventricular hypertrophy associated with significant aortic stenosis. Lumen diameter was measured at 96 points in 32 defined coronary segments or major branches. Measurements were scaled to the catheter, corrected for imaging distortion, and had a mean repeat measurement error of 0.12 mm. When sex, anatomic dominance, and branch length were accounted for, normal lumen diameter at each of the standard anatomic points could usually be specified with a population variance of +/- 0.6 mm or less (SD) and coefficient of variation of less than 0.25 (SD/mean). For example, the left main artery measured 4.5 +/- 0.5 mm, the proximal left anterior descending coronary artery (LAD) 3.7 +/- 0.4 mm, and the distal LAD 1.9 +/- 0.4 mm. For the LAD, lumen diameter was not affected by anatomic dominance (right versus left), but for the right coronary artery, proximal diameter varied between 3.9 +/- 0.6 and 2.8 +/- 0.5 mm (p less than 0.01) and for the left circumflex, between 3.4 +/- 0.5 and 4.2 +/- 0.6 mm (p less than 0.01). Women had smaller epicardial arterial diameter than men (-9%; p less than 0.001), even after normalization for body surface area (p less than 0.01). Branch artery caliber was unaffected by the anatomic dominance but increased with branch length, expressed as a fraction of the origin-to-apex distance (p less than 0.001). Lumen diameter was not affected by age or by vessel tortuosity but was significantly increased among men with left ventricular hypertrophy (+ 17%; p less than 0.001) or dilated cardiomyopathy (+ 12%; p less than 0.001).
CONCLUSIONS: This is a reference normal data set against which to compare lumen dimensions in various pathological states. It should be of particular value in the investigation of diffuse atherosclerotic disease.

Entities:  

Mesh:

Year:  1992        PMID: 1535570     DOI: 10.1161/01.cir.86.1.232

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  144 in total

Review 1.  Multislice computed tomography of the coronary arteries.

Authors:  Jens Rodenwaldt
Journal:  Eur Radiol       Date:  2003-01-22       Impact factor: 5.315

Review 2.  Coronary artery anatomy and variants.

Authors:  Roberto Malagò; Andrea Pezzato; Camilla Barbiani; Ugolino Alfonsi; Lisa Nicolì; Giuliana Caliari; Roberto Pozzi Mucelli
Journal:  Pediatr Radiol       Date:  2011-11-30

3.  Integrated ultrasound and photoacoustic probe for co-registered intravascular imaging.

Authors:  Wei Wei; Xiang Li; Qifa Zhou; K Kirk Shung; Zhongping Chen
Journal:  J Biomed Opt       Date:  2011-10       Impact factor: 3.170

4.  Dual-element needle transducer for intravascular ultrasound imaging.

Authors:  Sangpil Yoon; Min Gon Kim; Jay A Williams; Changhan Yoon; Bong Jin Kang; Nestor Cabrera-Munoz; K Kirk Shung; Hyung Ham Kim
Journal:  J Med Imaging (Bellingham)       Date:  2015-04-13

5.  Normal Proximal Coronary Artery Diameters in Adults from India as Assessed by Computed Tomography Angiography.

Authors:  Manjappa Mahadevappa; Madhav Hegde; Ravi Math
Journal:  J Clin Diagn Res       Date:  2016-05-01

6.  Nitric oxide transport in an axisymmetric stenosis.

Authors:  Xiao Liu; Yubo Fan; X Yun Xu; Xiaoyan Deng
Journal:  J R Soc Interface       Date:  2012-05-16       Impact factor: 4.118

7.  Study on motion artifacts in coronary arteries with an anthropomorphic moving heart phantom on an ECG-gated multidetector computed tomography unit.

Authors:  Marcel J W Greuter; Joost Dorgelo; Wim G J Tukker; Matthijs Oudkerk
Journal:  Eur Radiol       Date:  2005-03-18       Impact factor: 5.315

8.  Impact of Reconstruction Algorithms and Gender-Associated Anatomy on Coronary Calcium Scoring with CT: An Anthropomorphic Phantom Study.

Authors:  Qin Li; Songtao Liu; Kyle J Myers; Marios A Gavrielides; Rongping Zeng; Berkman Sahiner; Nicholas Petrick
Journal:  Acad Radiol       Date:  2016-09-22       Impact factor: 3.173

9.  Magnetic resonance imaging of coronary artery occlusions in the navigator technique.

Authors:  Thomas Wittlinger; Thomas Voigtländer; Martin Rohr; Jürgen Meyer; Martin Thelen; Karl Friedrich Kreitner; Peter Kalden
Journal:  Int J Cardiovasc Imaging       Date:  2002-06       Impact factor: 2.357

10.  Angled-focused 45 MHz PMN-PT single element transducer for intravascular ultrasound imaging.

Authors:  Sangpil Yoon; Jay Williams; Bong Jin Kang; Changhan Yoon; Nestor Cabrera-Munoz; Jong Seob Jeong; Sang Goo Lee; K Kirk Shung; Hyung Ham Kim
Journal:  Sens Actuators A Phys       Date:  2015-06-01       Impact factor: 3.407

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.