Abstract

OBJECTIVES: There may be a risk of greater ion release for surface-enlarged implants than conventionally turned components. The major aim of the present paper was to investigate whether a correlation exists between ion release and a surface roughness relevant for today's commercial implants. Other aims were to compare ion release after two insertion times and concentration in bone tissue as a function of distance from the implant surface.
MATERIAL AND METHODS: Lactic acid aqueous solution (pH=2.3) and phosphate-buffered saline were used for the in vitro investigation. For the in vivo investigation, synchrotron radiation X-ray fluorescence (SRXRF) spectroscopy and secondary ion mass spectroscopy (SIMS) were performed 12 weeks and 1 year after implantation in rabbit tibiae.
RESULTS: The average height deviation (S(a)) was 0.7, 1.27, 1.43 and 2.21 microm, respectively, for the four surfaces investigated. No difference in ion release was found in vitro. In vivo, SRXRF demonstrated slightly higher values for the roughest surface up to a distance of 400 microm from the implant surface; thereafter no difference was found. SIMS demonstrated no difference in ion release for the roughest and smoothest surfaces, but slightly more titanium in bone tissue after 1 year than after 12 weeks. Titanium rapidly decreased with distance from the implant surface.
CONCLUSION: At a level relevant for commercial oral implants, no correlation was found between increasing roughness and ion release, neither in vitro nor in vivo.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15355391     DOI: 10.1111/j.1600-0501.2004.01053.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  14 in total

1.  Long-term durability of orthodontic mini-implants.

Authors:  Mona Aly Abbassy; Ahmed Samir Bakry; Khalid Hashim Zawawi; Ali Habib Hassan
Journal:  Odontology       Date:  2017-08-24       Impact factor: 2.634

2.  Dental implant surfaces after insertion in bone: an in vitro study in four commercial implant systems.

Authors:  Herbert Deppe; Carolina Wolff; Florian Bauer; Ricarda Ruthenberg; Anton Sculean; Thomas Mücke
Journal:  Clin Oral Investig       Date:  2017-10-24       Impact factor: 3.573

Review 3.  Are clinical findings of systemic titanium dispersion following implantation explained by available in vitro evidence? An evidence-based analysis.

Authors:  Justin Paul Curtin; Minji Wang
Journal:  J Biol Inorg Chem       Date:  2017-05-17       Impact factor: 3.358

4.  An electrochemical impedance investigation of the behaviour of anodically oxidised titanium in human plasma and cognate fluids, relevant to dental applications.

Authors:  B Bozzini; P Carlino; L D'Urzo; V Pepe; C Mele; F Venturo
Journal:  J Mater Sci Mater Med       Date:  2008-06-27       Impact factor: 3.896

5.  Positive Material Identification testing of dental implant to correlate their compositions with allergic conditions.

Authors:  Avadhesh Kumar Chaubey; Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  J Oral Biol Craniofac Res       Date:  2019-05-17

6.  Titanium Ions Play a Synergistic Role in the Activation of NLRP3 Inflammasome in Jurkat T Cells.

Authors:  Xiao Li; Li Tang; Donghui Chen
Journal:  Inflammation       Date:  2020-08       Impact factor: 4.657

7.  Vitamin D deficiency in early implant failure: two case reports.

Authors:  Tobias Fretwurst; Sebastian Grunert; Johan P Woelber; Katja Nelson; Wiebke Semper-Hogg
Journal:  Int J Implant Dent       Date:  2016-11-25

8.  Potential Causes of Titanium Particle and Ion Release in Implant Dentistry: A Systematic Review.

Authors:  Rafael Delgado-Ruiz; Georgios Romanos
Journal:  Int J Mol Sci       Date:  2018-11-13       Impact factor: 5.923

Review 9.  Prevalence of Peri-Implantitis in Implants with Turned and Rough Surfaces: a Systematic Review.

Authors:  Nikola Saulacic; Benoit Schaller
Journal:  J Oral Maxillofac Res       Date:  2019-03-31

10.  Excessive production of mitochondrion‑derived reactive oxygen species induced by titanium ions leads to autophagic cell death of osteoblasts via the SIRT3/SOD2 pathway.

Authors:  Siqian Wang; Jingyuan Yang; Tingting Lin; Shengbing Huang; Jianfeng Ma; Xin Xu
Journal:  Mol Med Rep       Date:  2020-04-24       Impact factor: 2.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.