BACKGROUND: We prospectively evaluated a newly introduced minimal extracorporeal circulation system (Jostra MECC System; Jostra AG, Hirrlingen, Germany) for aortic valve surgery. METHOD: In a prospective, randomized study, 100 patients underwentaortic valve replacement either with standard cardiopulmonary bypass (n = 50, group B) or with the MECC System (n = 50, group B). The myocardial protection and the left vent were identical for the two groups. The intrapericardial suction device was never used (only the cell salvage device was used) to reduce the air-blood contact area. RESULTS: No significant differences were noted in patient characteristics and operative data between groups. Operative mortality (<30 days) was 2% for group A and 4% for group B (difference not significant). From the preoperative period to the postoperative period, the increase in C-reactive protein was significantly higher for group B (P <.001). The postoperative troponin I level was significantly lower in group A (mean 4.65 +/- 2.9 microg/L at 24 hours) than in group B (8.2 +/- 4.4 microg/L, P <.03). On the other hand, the MECC System was associated with platelet preservation. Renal function was better preserved and the neurologic event rate was significantly lower for the MECC group (P <.02). CONCLUSION: The MECC System is safe and allows aortic valve replacement under the most favorable conditions. The system is more biocompatible than standard cardiopulmonary bypass and provides a good postoperative biologic profile and good clinical results, particularly for high-risk patients.
RCT Entities:
BACKGROUND: We prospectively evaluated a newly introduced minimal extracorporeal circulation system (Jostra MECC System; Jostra AG, Hirrlingen, Germany) for aortic valve surgery. METHOD: In a prospective, randomized study, 100 patients underwent aortic valve replacement either with standard cardiopulmonary bypass (n = 50, group B) or with the MECC System (n = 50, group B). The myocardial protection and the left vent were identical for the two groups. The intrapericardial suction device was never used (only the cell salvage device was used) to reduce the air-blood contact area. RESULTS: No significant differences were noted in patient characteristics and operative data between groups. Operative mortality (<30 days) was 2% for group A and 4% for group B (difference not significant). From the preoperative period to the postoperative period, the increase in C-reactive protein was significantly higher for group B (P <.001). The postoperative troponin I level was significantly lower in group A (mean 4.65 +/- 2.9 microg/L at 24 hours) than in group B (8.2 +/- 4.4 microg/L, P <.03). On the other hand, the MECC System was associated with platelet preservation. Renal function was better preserved and the neurologic event rate was significantly lower for the MECC group (P <.02). CONCLUSION: The MECC System is safe and allows aortic valve replacement under the most favorable conditions. The system is more biocompatible than standard cardiopulmonary bypass and provides a good postoperative biologic profile and good clinical results, particularly for high-risk patients.
Authors: Aziz U Momin; Mansour T A Sharabiani; Emadin Kidher; Ali Najefi; John W Mulholland; Barnaby C Reeves; Gianni D Angelini; Jon R Anderson Journal: Interact Cardiovasc Thorac Surg Date: 2013-06-28
Authors: Hannu Kokki; Martin Maaroos; Sten Ellam; Jari Halonen; Ilkka Ojanperä; Merja Ranta; Veli-Pekka Ranta; Aleksandra Tolonen; Oscar Lindberg; Matias Viitala; Juha Hartikainen Journal: Eur J Clin Pharmacol Date: 2018-03-09 Impact factor: 2.953
Authors: Timothy Cheng; Rajas Barve; Yeu Wah Michael Cheng; Andrew Ravendren; Amna Ahmed; Steven Toh; Christopher J Goulden; Amer Harky Journal: JTCVS Open Date: 2021-10-01