Literature DB >> 15351980

Multiplex bead array assays for detection of soluble cytokines: comparisons of sensitivity and quantitative values among kits from multiple manufacturers.

Sameena S Khan1, Meghan S Smith, Debra Reda, Anthony F Suffredini, J Philip McCoy.   

Abstract

BACKGROUND: Multiplex bead array assays permit simultaneous cytometric quantitation of multiple cytokines in solution by capturing these to spectrally distinct beads. Because several manufacturers offer reagents to quantitate the same cytokines on a single instrument, a comparison should be made to determine whether these kits yield similar data and whether these data are comparable to enzyme-linked immunosorbent assay (ELISA).
METHODS: This study compared cytokine detection kits by using Luminex 100. Twenty-six serum samples from seven subjects were analyzed for interferon-gamma, interleukins 1beta, 6, and 8, and tumor necrosis factor-alpha by using multiplex kits from LINCO Research, Bio-Rad Laboratories, R&D Systems, and BioSource International. Each assay was performed according to the manufacturers' specifications. Standard curves were generated by using reference concentrations supplied by each manufacturer. ELISAs for interleukin-8 were performed by using kits from R&D and BioSource.
RESULTS: Cytokine levels followed similar patterns, although absolute concentrations differed among kits. ELISA and Luminex values for interleukin-8 were similar in kits from the same manufacturer.
CONCLUSIONS: Because relative cytokine measurements are often valuable when performed serially, it may be possible to make interlaboratory comparisons by using different kits. When comparison of absolute values is crucial, kits from the same supplier should be used. Within-vendor, bead array, and ELISA values appear comparable.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15351980     DOI: 10.1002/cyto.b.20021

Source DB:  PubMed          Journal:  Cytometry B Clin Cytom        ISSN: 1552-4949            Impact factor:   3.058


  103 in total

1.  Measurement of inflammatory cytokines by multicytokine assay in tears of patients with glaucoma topically treated with chronic drugs.

Authors:  L Malvitte; T Montange; A Vejux; C Baudouin; A M Bron; C Creuzot-Garcher; G Lizard
Journal:  Br J Ophthalmol       Date:  2006-08-30       Impact factor: 4.638

2.  Comparison of mRNA and protein measures of cytokines following vaccination with human papillomavirus-16 L1 virus-like particles.

Authors:  Fatma M Shebl; Ligia A Pinto; Alfonso García-Piñeres; Richard Lempicki; Marcus Williams; Clayton Harro; Allan Hildesheim
Journal:  Cancer Epidemiol Biomarkers Prev       Date:  2010-03-23       Impact factor: 4.254

3.  Alteration of tear cytokine balance by eye closure: analysis by multicytokine assay.

Authors:  Eisuke Uchino; Shozo Sonoda; Kumiko Nakao; Taiji Sakamoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-10-11       Impact factor: 3.117

4.  Inflammatory cytokine of basal and reflex tears analysed by multicytokine assay.

Authors:  S Sonoda; E Uchino; K Nakao; T Sakamoto
Journal:  Br J Ophthalmol       Date:  2006-01       Impact factor: 4.638

5.  Simultaneous detection of antibodies to six nonhuman-primate viruses by multiplex microbead immunoassay.

Authors:  Imran H Khan; Sara Mendoza; Joann Yee; Matthew Deane; Kodumudi Venkateswaran; Shan S Zhou; Peter A Barry; Nicholas W Lerche; Paul A Luciw
Journal:  Clin Vaccine Immunol       Date:  2006-01

6.  Multiplex bead array assays: performance evaluation and comparison of sensitivity to ELISA.

Authors:  Mohamed F Elshal; J Philip McCoy
Journal:  Methods       Date:  2006-04       Impact factor: 3.608

7.  Magnet Patterned Superparamagnetic Fe3 O4 /Au Core-Shell Nanoplasmonic Sensing Array for Label-Free High Throughput Cytokine Immunoassay.

Authors:  Yuxin Cai; Jingyi Zhu; Jiacheng He; Wen Yang; Chao Ma; Feng Xiong; Feng Li; Weiqiang Chen; Pengyu Chen
Journal:  Adv Healthc Mater       Date:  2019-01-15       Impact factor: 9.933

Review 8.  Pushing the frontiers of T-cell vaccines: accurate measurement of human T-cell responses.

Authors:  Fadi Saade; Stacey Ann Gorski; Nikolai Petrovsky
Journal:  Expert Rev Vaccines       Date:  2012-12       Impact factor: 5.217

Review 9.  Early diagnosis of disease using microbead array technology: A review.

Authors:  Sanam Foroutan Parsa; Atieh Vafajoo; Azin Rostami; Reza Salarian; Mohammad Rabiee; Navid Rabiee; Ghazal Rabiee; Mohammadreza Tahriri; Amir Yadegari; Daryoosh Vashaee; Lobat Tayebi; Michael R Hamblin
Journal:  Anal Chim Acta       Date:  2018-05-04       Impact factor: 6.558

Review 10.  Development and implementation of a proficiency testing program for Luminex bead-based cytokine assays.

Authors:  Heather E Lynch; Ana M Sanchez; M Patricia D'Souza; Wes Rountree; Thomas N Denny; Michael Kalos; Gregory D Sempowski
Journal:  J Immunol Methods       Date:  2014-05-04       Impact factor: 2.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.