Human biological reactions at the interface between bone tissue and polymethylmethacrylate cement.

J X Lu1, Z W Huang, P Tropiano, B Clouet D'Orval, M Remusat, J Dejou, J-P Proust, D Poitout.   

Abstract

This study investigated cytotoxicity of cement fragments harvested from two prosthesis revisions by the MTT test using L929 fibroblasts and human osteoblasts. The results did not show any toxicity of the extracts prepared after 48 and 78 months implantation. We consider that no MMA monomer has been released from the cement fragments. Histological studies on undecalcified samples harvested around revising prosthesis from 11 patients were used to evaluate tissue reactions at the bone-cement interface after 2-168 months implantation. Cement and prosthesis particles (5-35 microm) either dispersed or forming a layer were observed. A fibrous tissue layer, osteolysis, and osteonecrosis areas were observed at the interface. Besides, fibroblasts, macrophages, and multinucleated giant cells were also observed. New bone formation with osteoid, osteoblasts, and endochondral ossification with fibrocartilaginous tissue has been observed. The tissue reactions seemed to decrease with time. However, osseous trabeculae fractures were observed in the samples after 19 months. Although we consider that monomer toxicity, exothermic reaction, and particles formation may cause short-term prosthesis loosening; the trabeculae fractures may be due to prosthesis and bone cement micromovements. This fractures and particles formation may cause long-term prosthesis loosening.

Entities:  

Year:  2002        PMID: 15348569     DOI: 10.1023/a:1016135410934

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  22 in total

1.  THE ELIMINATION OF SLIP BETWEEN PROSTHESIS AND FEMUR.

Authors:  J CHARNLEY; J KETTLEWELL
Journal:  J Bone Joint Surg Br       Date:  1965-02

Review 2.  Cellular events in the mechanisms of prosthesis loosening.

Authors:  A Pizzoferrato; G Ciapetti; S Stea; A Toni
Journal:  Clin Mater       Date:  1991

3.  The effects of intramedullary methylmethacrylate and reaming on the circulation of the tibia after osteotomy and plate fixation in dogs.

Authors:  W G Sorensen; J D Bloom; P J Kelly
Journal:  J Bone Joint Surg Am       Date:  1979-04       Impact factor: 5.284

4.  Osteolysis in alloarthroplasty of the hip. The role of bone cement fragmentation.

Authors:  H G Willert; H Bertram; G H Buchhorn
Journal:  Clin Orthop Relat Res       Date:  1990-09       Impact factor: 4.176

5.  EPR study of free radicals in PMMA bone cement: a feasibility study.

Authors:  J B Park; R C Turner; P E Atkins
Journal:  Biomater Med Devices Artif Organs       Date:  1980

6.  Decreased blood perfusion in canine tibial diaphysis after filling with acrylic bone cement compared with inert bone wax.

Authors:  J Stürup; J Madsen; E Tøndevold; J S Jensen
Journal:  Acta Orthop Scand       Date:  1990-04

7.  Histological evaluation of cortical bone reaction to PMMA cement.

Authors:  L N Jensen; J Stürup; M Kramhøft; J S Jensen
Journal:  Acta Orthop Belg       Date:  1991       Impact factor: 0.500

Review 8.  Mechanism and clinical significance of wear debris-induced osteolysis.

Authors:  H C Amstutz; P Campbell; N Kossovsky; I C Clarke
Journal:  Clin Orthop Relat Res       Date:  1992-03       Impact factor: 4.176

9.  In vitro effects of bone cements on the cell cycle of osteoblast-like cells.

Authors:  D Granchi; S Stea; G Ciapetti; L Savarino; D Cavedagna; A Pizzoferrato
Journal:  Biomaterials       Date:  1995-10       Impact factor: 12.479

10.  Acrylic fragmentation in total hip replacements and its biological consequences.

Authors:  M Jasty; W Jiranek; W H Harris
Journal:  Clin Orthop Relat Res       Date:  1992-12       Impact factor: 4.176

View more
  10 in total

1.  Reconstruction of bony facial contour deficiencies with polymethylmethacrylate implants: case report.

Authors:  Ruy C C Abdo Filho; Thais M Oliveira; Natalino Lourenço Neto; Carla Gurgel; Ruy C C Abdo
Journal:  J Appl Oral Sci       Date:  2011-08       Impact factor: 2.698

2.  Experimental micromechanics of the cement-bone interface.

Authors:  Kenneth A Mann; Mark A Miller; Richard J Cleary; Dennis Janssen; Nico Verdonschot
Journal:  J Orthop Res       Date:  2008-06       Impact factor: 3.494

3.  Loss of cement-bone interlock in retrieved tibial components from total knee arthroplasties.

Authors:  Mark A Miller; Jacklyn R Goodheart; Timothy H Izant; Clare M Rimnac; Richard J Cleary; Kenneth A Mann
Journal:  Clin Orthop Relat Res       Date:  2013-08-24       Impact factor: 4.176

4.  Semi-degradable poly(β-amino ester) networks with temporally controlled enhancement of mechanical properties.

Authors:  David L Safranski; Daiana Weiss; J Brian Clark; W Robert Taylor; Ken Gall
Journal:  Acta Biomater       Date:  2014-04-24       Impact factor: 8.947

5.  Designer Dual Therapy Nanolayered Implant Coatings Eradicate Biofilms and Accelerate Bone Tissue Repair.

Authors:  Jouha Min; Ki Young Choi; Erik C Dreaden; Robert F Padera; Richard D Braatz; Myron Spector; Paula T Hammond
Journal:  ACS Nano       Date:  2016-03-02       Impact factor: 15.881

6.  In vivo loss of cement-bone interlock reduces fixation strength in total knee arthroplasties.

Authors:  Jacklyn R Goodheart; Mark A Miller; Kenneth A Mann
Journal:  J Orthop Res       Date:  2014-04-29       Impact factor: 3.494

7.  Surface modification of fiber reinforced polymer composites and their attachment to bone simulating material.

Authors:  M P Hautamäki; M Puska; A J Aho; H M Kopperud; P K Vallittu
Journal:  J Mater Sci Mater Med       Date:  2013-02-26       Impact factor: 3.896

8.  Biological response of new activated acrylic bone cements with antiseptic properties. Histomorphometric analysis.

Authors:  B de la Torre; M Salvado; M A González Corchón; B Vázquez; F Collía; J A De Pedro; J San Román
Journal:  J Mater Sci Mater Med       Date:  2007-01-11       Impact factor: 4.727

Review 9.  Bone cement as a local chemotherapeutic drug delivery carrier in orthopedic oncology: A review.

Authors:  Sunjeev S Phull; Alireza Rahimnejad Yazdi; Michelle Ghert; Mark R Towler
Journal:  J Bone Oncol       Date:  2020-12-16       Impact factor: 4.072

10.  Customized polymethyl methacrylate implants for the reconstruction of craniofacial osseous defects.

Authors:  André Luis Fernandes da Silva; Alexandre Meireles Borba; Niverso Rodrigues Simão; Fábio Luis Miranda Pedro; Alvaro Henrique Borges; Michael Miloro
Journal:  Case Rep Surg       Date:  2014-06-30
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.