Abstract

The functional restoration of a joint damaged by trauma or disease is obtained by prosthetic surgery. In particular the implantation of hip prostheses is regarded as routine in orthopedic surgery and thorough research has been developed in this field. The prosthetic replacement of the knee and even more so the ankle and elbow occurs less frequently in clinical practice and has been studied less intensively. The results of artifical hip replacement are generally good, both in terms of pain relief and the restoration of satisfactory joint function. Nevertheless, as time passes, a high rate of failures have been recorded due to prosthesis infections, fracture and wearing of the prosthetic components and prosthesis loosening by various causes. The use of ultra-filtered air and laminar flow in operating theatres and antibiotic prophylaxis have dramatically reduced the incidence of infections in total hip arthroplasty. Thanks to the setting up of new stem configurations and the use of superalloys that are highly resistant to fatigue failure, the fracture of the femoral component has been virtually eliminated as a complication of total hip arthroplasty replacements. Loosening is thus the most frequent complication in total hip replacement.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 10149133     DOI: 10.1016/0267-6605(91)90057-m

Source DB:  PubMed          Journal:  Clin Mater        ISSN: 0267-6605


  7 in total

1.  Visual Pattern and Serial Quantitation of 18F-Sodium Fluoride PET/CT in Asymptomatic Patients After Hip and Knee Arthroplasty.

Authors:  Hye Joo Son; Young Jin Jeong; Hyun Jin Yoon; Lih Wang; Hyeon Jun Kim; Jong-Hwan Park; Do-Young Kang
Journal:  Nucl Med Mol Imaging       Date:  2016-07-13

2.  Flow cytometry as a diagnostic tool for identifying total hip arthroplasty loosening and differentiating between septic and aseptic cases.

Authors:  Maria Ovrenovits; Emilios E Pakos; Georgios Vartholomatos; Nikolaos K Paschos; Theodoros A Xenakis; Grigorios I Mitsionis
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-07-12

3.  Human biological reactions at the interface between bone tissue and polymethylmethacrylate cement.

Authors:  J X Lu; Z W Huang; P Tropiano; B Clouet D'Orval; M Remusat; J Dejou; J-P Proust; D Poitout
Journal:  J Mater Sci Mater Med       Date:  2002-08       Impact factor: 3.896

Review 4.  The Biologic Response to Polyetheretherketone (PEEK) Wear Particles in Total Joint Replacement: A Systematic Review.

Authors:  Ashley A Stratton-Powell; Kinga M Pasko; Claire L Brockett; Joanne L Tipper
Journal:  Clin Orthop Relat Res       Date:  2016-07-18       Impact factor: 4.176

5.  Retroacetabular osteolytic lesions behind well-fixed prosthetic cups: pilot study of bearings-retaining surgery.

Authors:  Luca Pierannunzii; Florian Fischer; Marco d'Imporzano
Journal:  J Orthop Traumatol       Date:  2008-10-25

6.  Septic failure is not a septic loosening: A case report of a failed shoulder prosthesis.

Authors:  Yde Engelsma; Pieter Buma; Pieter C Geervliet; Arthur Van Noort
Journal:  Int J Shoulder Surg       Date:  2012-10

7.  In vitro biocompatibility testing of some synthetic polymers used for the achievement of nervous conduits.

Authors:  R Mihai; I P Florescu; V Coroiu; A Oancea; M Lungu
Journal:  J Med Life       Date:  2011-08-25
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.