Abstract
Elastic modulus (EM), initial fracture strength (FS) and flexural fatigue limit (FFL) of dental restorative materials were measured in a simulated oral environment to correlate mechanical response under the influence of water with the chemical nature of the test materials under investigation. One resin composite (RC; Tetric Ceram, Ivoclar-Vivadent Corp., Liechtenstein), an ion-leaching resin composite (ILRC; Ariston pHc, Ivoclar-Vivadent Corp., Liechtenstein) a compomer (CO; Dyract AP, Dentsply Corp., USA) and a glass-ionomer cement (GIC; Ketac Molar, 3MEspe Corp., Germany) were tested. Static EM, FS and dynamic FFL experiments were performed. The FFL was determined under cyclic loading for 10(5) cycles in terms of a staircase approach. The materials were stored for 1, 8, 30, 90 and 180 days in 37 degrees C distilled water, respectively. The RC degraded over time due to water adsorption followed by failure within the resin matrix. The ILRC suffered from a pronounced decrease in FS as well as in FFL due to a constant ion-leaching and macroscopic crack growth. CO failed over time due to resin-filler interface cracking. The GIC exhibited improved mechanical performance over time due to a post-hardening mechanism. The results reveal the necessity for substantial preclinical evaluation of direct restorative materials. The material parameters under investigation are capable of predicting clinical performance over time.Entities:
Year: 2003 PMID: 15348497 DOI: 10.1023/b:jmsm.0000004001.73640.4c
Source DB: PubMed Journal: J Mater Sci Mater Med ISSN: 0957-4530 Impact factor: 3.896