Abstract

The torsional strength of plasma sprayed hydroxyapatite (HA) coatings was studied under static and cyclic loading. The torsional shear tests were conducted in a frustum test device developed in this laboratory, which adapted to various coating thicknesses. The interfacial fatigue resistance was measured in terms of interfacial fatigue strength defined as the average maximum stress (tau(fmax)). A staircase fatigue method was employed to determine the interfacial fatigue strength; this method resolved the uncertainty in detecting coating failure during torsion fatigue. The values for coating shear strength and shear fatigue strength obtained from the torsional tests did not differ from those obtained by previous tensional shear tests in this laboratory. The fatigue strength of one million cycles was about 35% lower than static shear strength. This finding might be used for estimating fatigue life span without cyclic loading tests.

Entities:  

Year:  2003        PMID: 15348452     DOI: 10.1023/a:1022927012983

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  12 in total

1.  Fatigue behavior of calcium phosphate coatings with different stability under dry and wet conditions.

Authors:  J A Clemens; J G Wolke; C P Klein; K de Groot
Journal:  J Biomed Mater Res       Date:  1999

2.  Biaxial residual stress states of plasma-sprayed hydroxyapatite coatings on titanium alloy substrate.

Authors:  Y C Yang; E Chan; B H Hwang; S Y Lee
Journal:  Biomaterials       Date:  2000-07       Impact factor: 12.479

3.  Effects of cyclic bending and physiological solution on plasma-sprayed hydroxylapatite coatings of varying crystallinity.

Authors:  J A Haynes; E D Rigney; G M Janowski
Journal:  J Biomed Mater Res       Date:  1999

4.  Mechanical and chemical consequences of the residual stresses in plasma sprayed hydroxyapatite coatings.

Authors:  V Sergo; O Sbaizero; D R Clarke
Journal:  Biomaterials       Date:  1997-03       Impact factor: 12.479

5.  Is staircase walking a risk for the fixation of hip implants?

Authors:  G Bergmann; F Graichen; A Rohlmann
Journal:  J Biomech       Date:  1995-05       Impact factor: 2.712

6.  In vitro mechanical integrity of hydroxyapatite coatings on Ti-6Al-4V implants under shear loading.

Authors:  C Zhang; Y Leng; J Chen
Journal:  J Biomed Mater Res       Date:  2001-09-05

7.  Fatigue properties of hydroxyapatite-coated dental implants after exposure to a periodontal pathogen.

Authors:  D P Mukherjee; N R Dorairaj; D K Mills; D Graham; J T Krauser
Journal:  J Biomed Mater Res       Date:  2000-09

8.  Plasma-sprayed hydroxyapatite (HA) coatings with flame-spheroidized feedstock: microstructure and mechanical properties.

Authors:  S W Kweh; K A Khor; P Cheang
Journal:  Biomaterials       Date:  2000-06       Impact factor: 12.479

9.  Plasma sprayed hydroxyapatite coatings on titanium substrates. Part 2: optimisation of coating properties.

Authors:  Y C Tsui; C Doyle; T W Clyne
Journal:  Biomaterials       Date:  1998-11       Impact factor: 12.479

10.  Interfacial bond strength of electrophoretically deposited hydroxyapatite coatings on metals.

Authors:  M Wei; A J Ruys; M V Swain; S H Kim; B K Milthorpe; C C Sorrell
Journal:  J Mater Sci Mater Med       Date:  1999-07       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.