Evaluation of mechanical and corrosion biocompatibility of TiTa alloys.

E A Trillo1, C Ortiz, P Dickerson, R Villa, S W Stafford, L E Murr.   

Abstract

As-received and heat-treated Ti40Ta and Ti50Ta alloys were evaluated to determine their corrosion as well as mechanical performances and compared to Ti6A14V, a common material utilized for orthopedic (surgical) implants. Anodic potentiodynamic tests performed in Plasmalyte showed that all samples, except for the Ti50Ta specimen aged at 400 degrees C for 3 h gave a curve similar to that of Ti6A14V. Optical and TEM microscopy was performed to determine as-received and heat-treated microstructures. As-received materials showed an alpha precipitate in an alpha+beta and martensite matrix. Samples that were aged at 400 degrees C increased in the density and the length of the alpha precipitate. Vickers hardness measurements were performed to get an approximation of the tensile strengths. Aged Ti40Ta and Ti50Ta specimens produced the highest tensile values when compared to the Ti6A14V material, representing a 31% and 56% increase for the 3 h samples and an 18% and 58% increase for the 10 h samples. Of all the materials studied the Ti50Ta specimen aged for 10 h exhibited the best biocompatibility showing excellent corrosion resistance combined with the highest tensile strength (1089 MPa and 58% harder/stronger than Ti6A14V). Copyright 2001 Kluwer Academic Publishers

Entities:  

Year:  2001        PMID: 15348288     DOI: 10.1023/a:1011210101895

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  8 in total

1.  Systemic titanium levels in rabbits with a titanium implant in the absence of wear.

Authors:  P D Bianco; P Ducheyne; J M Cuckler
Journal:  J Mater Sci Mater Med       Date:  1997-09       Impact factor: 3.896

2.  A new balloon-expandable tantalum stent (Strecker-Stent) for the biliary system: preliminary experience.

Authors:  W Jaschke; K J Klose; E P Strecker
Journal:  Cardiovasc Intervent Radiol       Date:  1992 Nov-Dec       Impact factor: 2.740

3.  Histologic, biochemical, and ion analysis of tissue and fluids retrieved during total hip arthroplasty.

Authors:  L D Dorr; R Bloebaum; J Emmanual; R Meldrum
Journal:  Clin Orthop Relat Res       Date:  1990-12       Impact factor: 4.176

4.  Evaluation of the biocompatibility of titanium-tantalum alloy versus titanium.

Authors:  H Prigent; P Pellen-Mussi; G Cathelineau; M Bonnaure-Mallet
Journal:  J Biomed Mater Res       Date:  1998-02

5.  Changes in nonosseous tissue adjacent to titanium implants.

Authors:  G Meachim; D F Williams
Journal:  J Biomed Mater Res       Date:  1973-11

6.  In vivo metal-ion release from porous titanium-fiber material.

Authors:  P Ducheyne; G Willems; M Martens; J Helsen
Journal:  J Biomed Mater Res       Date:  1984-03

7.  Effects of acute, transient coronary occlusion on global and regional right ventricular function in humans.

Authors:  M S Verani; G W Guidry; J J Mahmarian; S Nishimura; T Athanasoulis; R Roberts; J L Lacy
Journal:  J Am Coll Cardiol       Date:  1992-12       Impact factor: 24.094

8.  Local accumulation of titanium released from a titanium implant in the absence of wear.

Authors:  P D Bianco; P Ducheyne; J M Cuckler
Journal:  J Biomed Mater Res       Date:  1996-06
  8 in total
  4 in total

1.  Effect of thermal treatments on tensile strength of commercially cast pure titanium and Ti-6Al-4V alloys.

Authors:  Sicknan Soares da Rocha; Gelson Luis Adabo; Luis Geraldo Vaz; Guilherme Elias Pessanha Henriques
Journal:  J Mater Sci Mater Med       Date:  2005-08       Impact factor: 3.896

Review 2.  Corrosion of Metallic Biomaterials: A Review.

Authors:  Noam Eliaz
Journal:  Materials (Basel)       Date:  2019-01-28       Impact factor: 3.623

3.  Influence of noble metals alloying additions on the corrosion behaviour of titanium in a fluoride-containing environment.

Authors:  F Rosalbino; S Delsante; G Borzone; G Scavino
Journal:  J Mater Sci Mater Med       Date:  2012-03-02       Impact factor: 3.896

4.  Effect of Manufacturing Process on the Biocompatibility and Mechanical Properties of Ti-30Ta Alloy.

Authors:  P Gill; N Munroe; C Pulletikurthi; S Pandya; W Haider
Journal:  J Mater Eng Perform       Date:  2011-07-01       Impact factor: 1.819

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.