Chemical and biological characteristics of low-temperature plasma treated ultra-high molecular weight polyethylene for biomedical applications.

C Klapperich1, L Pruitt, K Komvopoulos.   

Abstract

Several low-temperature radio-frequency (RF) plasma surface treatments were performed on ultra-high molecular weight polyethylene (UHMWPE) used in biomedical applications. Process gases included Ar, C3F6, CH4, hexamethyldisiloxane (HMDSO), and NH4. These treatments were carried out at pressures in the range of 64-400 mTorr, RF powers of 240-1200 W, and temperatures well below the melting point of UHMWPE. X-ray photoelectron spectroscopy (XPS) was used to obtain information about the surface characteristics of UHMWPE treated with the HMDSO, C3F6, and CH4 gases as a function of treatment conditions. XPS spectra of UHMWPE treated with C3F6 and CH4 and exposed to a laboratory environment for different time periods were examined in order to assess the stability of these treatments. It was found that for the C3F6 process gas the amount of fluorine at the surface decreased over time, whereas the oxygen content of the CH4 treated samples increased as a function of time. In vitro cytotoxicity of Ar, C3F6, CH4, and NH4 plasma treated samples was studied in light of 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) test results. The hemolytic nature of the various plasma treatments was evaluated using standard hemolysis tests. All of the samples tested in this study exhibited no cytotoxic and negligible hemolytic effects. The process parameters for several low-temperature plasma treatments demonstrating chemical and structural stability and good biocompatibility are discussed in conjunction with the broad applicability to other biomedical polymers. Copyright 2001 Kluwer Academic Publishers

Entities:  

Year:  2001        PMID: 15348272     DOI: 10.1023/a:1011232032413

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  10 in total

1.  Preclinical evaluation of prototype products.

Authors:  J C Park; D H Lee; H Suh
Journal:  Yonsei Med J       Date:  1999-12       Impact factor: 2.759

2.  Oxidation of ultrahigh molecular weight polyethylene characterized by Fourier Transform Infrared Spectrometry.

Authors:  M Goldman; M Lee; R Gronsky; L Pruitt
Journal:  J Biomed Mater Res       Date:  1997-10

3.  Comparison of the effects of gamma radiation and low temperature hydrogen peroxide gas plasma sterilization on the molecular structure, fatigue resistance, and wear behavior of UHMWPE.

Authors:  M Goldman; L Pruitt
Journal:  J Biomed Mater Res       Date:  1998-06-05

4.  Surface modification of polyethylene by plasma grafting with styrene for enhanced biocompatibility.

Authors:  K E Geckeler; R Gebhardt; H Grünwald
Journal:  Naturwissenschaften       Date:  1997-04

Review 5.  Design of nonthrombogenic polymer surfaces for blood-contacting medical devices.

Authors:  S W Kim; H Jacobs
Journal:  Blood Purif       Date:  1996       Impact factor: 2.614

6.  Rapid colorimetric assay for cellular growth and survival: application to proliferation and cytotoxicity assays.

Authors:  T Mosmann
Journal:  J Immunol Methods       Date:  1983-12-16       Impact factor: 2.303

7.  Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide.

Authors:  M D Ries; K Weaver; R M Rose; J Gunther; W Sauer; N Beals
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

8.  ESCA surface characterization of four IUPAC reference polymers.

Authors:  B D Ratner; D Leach-Scampavia; D G Castner
Journal:  Biomaterials       Date:  1993       Impact factor: 12.479

9.  Influence of plasma modification on biological properties of poly(ethylene terephthalate).

Authors:  J Pigłowski; I Gancarz; J Staniszewska-Kuś; D Paluch; M Szymonowicz; A Konieczny
Journal:  Biomaterials       Date:  1994-09       Impact factor: 12.479

10.  Blood compatibility of surfaces modified by plasma polymerization.

Authors:  Y S Yeh; Y Iriyama; Y Matsuzawa; S R Hanson; H Yasuda
Journal:  J Biomed Mater Res       Date:  1988-09
  10 in total
  1 in total

Review 1.  Biological effects of dynamic shear stress in cardiovascular pathologies and devices.

Authors:  Gaurav Girdhar; Danny Bluestein
Journal:  Expert Rev Med Devices       Date:  2008-03       Impact factor: 3.166

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.