Literature DB >> 15348190

Electrochemical behavior of nitinol alloy in Ringer's solution.

E X Sun1, S Fine, W B Nowak.   

Abstract

Corrosion behavior of Nitinol (nickel titanium) alloy has been examined in physiological Ringer's solution by means of electrochemical techniques (open-circuit potential measurement, potentiodynamic and potentiostatic polarizations) and capacitance measurements. The results show that the passive film is stable at open-circuit condition, but many of anodic current transients are observed at potentiodynamic and potentiostatic polarizations. The thickness of passive film decreased because of the occurrence of dissolution.

Entities:  

Year:  2002        PMID: 15348190     DOI: 10.1023/a:1019812729884

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  24 in total

Review 1.  The stent decade: 1987 to 1997. Stanford Stent Summit faculty.

Authors:  S N Oesterle; R Whitbourn; P J Fitzgerald; A C Yeung; S H Stertzer; M D Dake; P G Yock; R Virmani
Journal:  Am Heart J       Date:  1998-10       Impact factor: 4.749

Review 2.  The utility of superelasticity in medicine.

Authors:  T W Duerig; A R Pelton; D Stöckel
Journal:  Biomed Mater Eng       Date:  1996       Impact factor: 1.300

Review 3.  Studies and applications of NiTi shape memory alloys in the medical field in China.

Authors:  K Dai; Y Chu
Journal:  Biomed Mater Eng       Date:  1996       Impact factor: 1.300

4.  Effect of compressive straining on corrosion resistance of a shape memory Ni-Ti alloy in Ringer's solution.

Authors:  C Montero-Ocampo; H Lopez; A Salinas Rodriguez
Journal:  J Biomed Mater Res       Date:  1996-12

5.  Chemical modification of metallic implant surfaces with biofunctional proteins (Part 2). Corrosion resistance of a chemically modified NiTi alloy.

Authors:  K Endo
Journal:  Dent Mater J       Date:  1995-12       Impact factor: 2.102

6.  Laboratory and clinical analyses of nitinol wire.

Authors:  G F Andreasen; R E Morrow
Journal:  Am J Orthod       Date:  1978-02

7.  Surface corrosion of nitinol and stainless steel under clinical conditions.

Authors:  J W Edie; G F Andreasen; M P Zaytoun
Journal:  Angle Orthod       Date:  1981-10       Impact factor: 2.079

8.  The chloride corrosion behaviour of four orthodontic wires.

Authors:  N K Sarkar; W Redmond; B Schwaninger; A J Goldberg
Journal:  J Oral Rehabil       Date:  1983-03       Impact factor: 3.837

9.  Cytotoxic, allergic and genotoxic activity of a nickel-titanium alloy.

Authors:  D J Wever; A G Veldhuizen; M M Sanders; J M Schakenraad; J R van Horn
Journal:  Biomaterials       Date:  1997-08       Impact factor: 12.479

View more
  1 in total

1.  Ion Release and Surface Characterization of Nanostructured Nitinol during Long-Term Testing.

Authors:  Elena O Nasakina; Maria A Sudarchikova; Konstantin V Sergienko; Sergey V Konushkin; Mikhail A Sevost'yanov
Journal:  Nanomaterials (Basel)       Date:  2019-11-05       Impact factor: 5.076

  1 in total