Indoor air quality during renovation actions: a case study.

A A Abdel Hameed1, I H Yasser, I M Khoder.   

Abstract

A temporary renovation activity releases considerably high concentrations of particulate matter, viable and non-viable, into air. These pollutants are a potential contributor to unacceptable indoor air quality (IAQ). Particulate matter and its constituents lead, sulfate, nitrate, chloride, ammonium and fungi as well as fungal spores in air were evaluated in a building during renovation action. Suspended dust was recorded at a mean value of 6.1 mg m(-3) which exceeded the Egyptian limit values for indoor air (0.15 mg m(-3)) and occupational environments (5 mg m(-3)). The highest particle frequency (23%) of aerodynamic diameter (dae) was 1.7 microm. Particulate sulfate (SO(4)(2-)), nitrate (NO(3)(-)), chloride (Cl(-)), ammonium (NH(4)(+)) and lead components of suspended dust averaged 2960, 28, 1350, 100 and 13.3 microg m(-3), respectively. Viable fungi associated with suspended dust and that in air averaged 1.11 x 10(6) colony forming unit per gram (cfu g(-1)) and 92 colony forming unit per plate per hour (cfu p(-1) h(-1)), respectively. Cladosporium(33%), Aspergillus(25.6%), Alternaria(11.2%) and Penicillium(6.6%) were the most frequent fungal genera in air, whereas Aspergillus(56.8%), Penicillium(10.3%) and Eurotium(10.3%) were the most common fungal genera associated with suspended dust. The detection of Aureobasidium, Epicoccum, Exophiala, Paecilomyces, Scopulariopsis, Ulocladium and Trichoderma is an indication of moisture-damaged building materials. Alternaria, Aureobasidium, Cladosporium, Scopulariopsis and Nigrospora have dae > 5 microm whereas Aspergillus, Penicillium and Verticillium have dae < 5 microm which are suited to penetrate deeply into lungs. Particulate matter from the working area infiltrates the occupied zones if precautionary measures are inadequate. This may cause deterioration of IAQ, discomfort and acute health problems. Renovation should be carefully designed and managed, in order to minimize degradation of the indoor and outdoor air quality.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15346177     DOI: 10.1039/b402995j

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  8 in total

1.  Composition of heavy metals and airborne fibers in the indoor environment of a building during renovation.

Authors:  Mohd Talib Latif; Nor Hafizah Baharudin; Puvaneswary Velayutham; Normah Awang; Harimah Hamdan; Ruqyyah Mohamad; Mazlin B Mokhtar
Journal:  Environ Monit Assess       Date:  2010-12-23       Impact factor: 2.513

Review 2.  Aspergillus fumigatus morphology and dynamic host interactions.

Authors:  Frank L van de Veerdonk; Mark S Gresnigt; Luigina Romani; Mihai G Netea; Jean-Paul Latgé
Journal:  Nat Rev Microbiol       Date:  2017-09-18       Impact factor: 60.633

Review 3.  Molecular Mechanisms of Conidial Germination in Aspergillus spp.

Authors:  Tim J H Baltussen; Jan Zoll; Paul E Verweij; Willem J G Melchers
Journal:  Microbiol Mol Biol Rev       Date:  2019-12-04       Impact factor: 11.056

4.  Effects of Itraconazole and Micafungin on Aspergillus fumigatus Biofilms.

Authors:  Musang Liu; Hailin Zheng; Rong Zeng; Guanzhao Liang; Nan Zheng; Weida Liu
Journal:  Mycopathologia       Date:  2021-05-06       Impact factor: 2.574

5.  Trace metals in size-fractionated particulate matter in a Portuguese hospital: exposure risks assessment and comparisons with other countries.

Authors:  Klara Slezakova; Simone Morais; Maria do Carmo Pereira
Journal:  Environ Sci Pollut Res Int       Date:  2013-11-24       Impact factor: 4.223

6.  Humidity governs the wall-inhabiting fungal community composition in a 1600-year tomb of Emperor Yang.

Authors:  Yonghui Li; Zhi Huang; Evangelos Petropoulos; Yan Ma; Yang Shen
Journal:  Sci Rep       Date:  2020-05-21       Impact factor: 4.379

7.  Assessment of Individual-Level Exposure to Airborne Particulate Matter during Periods of Atmospheric Thermal Inversion.

Authors:  Rok Novak; Johanna Amalia Robinson; Tjaša Kanduč; Dimosthenis Sarigiannis; David Kocman
Journal:  Sensors (Basel)       Date:  2022-09-20       Impact factor: 3.847

Review 8.  Indoor air quality of everyday use spaces dedicated to specific purposes-a review.

Authors:  Mariusz Marć; Monika Śmiełowska; Jacek Namieśnik; Bożena Zabiegała
Journal:  Environ Sci Pollut Res Int       Date:  2017-11-30       Impact factor: 4.223

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.