Literature DB >> 15343538

Spacer endoprosthesis for the treatment of infected total hip arthroplasty.

Sridhar M Durbhakula1, John Czajka, Marc D Fuchs, Richard L Uhl.   

Abstract

We reviewed the treatment of infected total hip arthroplasty with a temporary spacer endoprosthesis. To fabricate the spacer, antibiotic-loaded cement was inserted into a specially designed mold. A central rod pin was superficially imbedded as an endoskeleton once the cement reached a doughy state. After polymerization, the final product was removed from the mold and inserted as an articulating spacer. Twenty patients were followed for an average of 38 months (range, 26-67 months). There were no recurrent or persistent infections. Eighteen patients underwent a successful 2-stage exchange. Two patients retained the spacer as a definitive treatment method. Complications with the spacer included 2 fractures and 2 dislocations. Overall, this cost-effective technique provided efficient local antibiotic delivery, early mobilization, facilitation of reimplantation, and improved patient satisfaction.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15343538     DOI: 10.1016/j.arth.2004.02.037

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  27 in total

1.  Mechanical effects, antimicrobial efficacy and cytotoxicity of usnic acid as a biofilm prophylaxis in PMMA.

Authors:  Sunghwan Kim; Robert Greenleaf; Mark Carl Miller; Latha Satish; Sandeep Kathju; Garth Ehrlich; J Christopher Post; Nicholas G Sotereanos; Paul Stoodley
Journal:  J Mater Sci Mater Med       Date:  2011-09-22       Impact factor: 3.896

2.  A technique for the fabrication of a reinforced moulded articulating cement spacer in two-stage revision total hip arthroplasty.

Authors:  Matthew Kent; Rajesh Rachha; Manoj Sood
Journal:  Int Orthop       Date:  2009-08-20       Impact factor: 3.075

Review 3.  Two-Stage Revision Arthroplasty for the Treatment of Prosthetic Joint Infection.

Authors:  Ryan S Charette; Christopher M Melnic
Journal:  Curr Rev Musculoskelet Med       Date:  2018-09

Review 4.  [Replacement of infected knee and hip endoprostheses].

Authors:  M Militz; V Bühren
Journal:  Chirurg       Date:  2010-04       Impact factor: 0.955

5.  The effect of endoskeleton on antibiotic impregnated cement spacer for treating deep hip infection.

Authors:  Kuo-Ti Peng; Liang-Tseng Kuo; Wei-Hsiu Hsu; Tsan-Wen Huang; Yao-Hung Tsai
Journal:  BMC Musculoskelet Disord       Date:  2011-01-13       Impact factor: 2.362

Review 6.  The Use of Antibiotic Impregnated Cement Spacers in the Treatment of Infected Total Joint Replacement: Challenges and Achievements.

Authors:  Omid Shahpari; Alireza Mousavian; Nafise Elahpour; Michael-Alexander Malahias; Mohammad H Ebrahimzadeh; Ali Moradi
Journal:  Arch Bone Jt Surg       Date:  2020-01

7.  Mechanical evaluation of hip cement spacer reinforcement with stainless steel Kirschner wires, titanium and carbon rods, and stainless steel mesh.

Authors:  Nobuhiro Kaku; Tomonori Tabata; Hiroshi Tsumura
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-11-25

8.  The use of a preformed spacer in two-stage revision of infected hip arthroplasties.

Authors:  F D'Angelo; L Negri; T Binda; G Zatti; P Cherubino
Journal:  Musculoskelet Surg       Date:  2011-04-09

Review 9.  Two-stage procedure in the treatment of late chronic hip infections--spacer implantation.

Authors:  Mohamed Sukeik; Fares S Haddad
Journal:  Int J Med Sci       Date:  2009-09-02       Impact factor: 3.738

10.  Mechanical behaviour of standardized, endoskeleton-including hip spacers implanted into composite femurs.

Authors:  T Thielen; S Maas; A Zuerbes; D Waldmann; K Anagnostakos; J Kelm
Journal:  Int J Med Sci       Date:  2009-09-03       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.